6.
7.
8.
NOTE: In the
an FPC number and the PIM number (always 0) is reported as a PIC number.
Figure 57: Installing a PIM
If necessary, arrange the cables to prevent them from dislodging or developing
stress points:
Secure each cable so that it is not supporting its own weight as it hangs
to the floor.
Place excess cable out of the way in a neatly coiled loop.
Use fasteners to maintain the shape of cable loops.
Press and release the power button to power on the router. Verify that the
LED lights steadily after you press the power button.
POWER
Verify that the PIM LEDs light steadily green to confirm that the PIM and its
ports are online and operational. For more information about PIM LEDs, see
"Field-Replaceable PIMs" on page 49.
You can also verify correct PIM functioning by issuing the
command described in the JUNOS System Basics and Services
pic-status
Command Reference.
show chassis fpc pic-status
AL AR M
O N
PO W ER
Replacing and Troubleshooting Hardware Components
command, the PIM slot number is reported as
ST AT US
1
G
PO RT
C O N FI
ST AT US
0
PO RT
Replacing Hardware Components
show chassis fpc
167