Simrad AP35 Autopilot
• Automatic Rudder test
• Transition Speed
• Autotrim work
• Master Reset of memories (only if required)
Enter the ISM as previously described. Go to "Dockside Settings" by
pressing STBD [>] button.
To access the Dockside settings, turn the course selector clockwise.
The display will show:
Actual boat type is selected by turning the rotary course selector. The
options are: Displacement or Planing.
Type of boat will affect the steering parameters, and the functions available
in the autopilot system. Select appropriate boat type and press STBD [>]
button.

Drive unit voltage selection

This menu option requires the installer to set the drive unit voltage to the
correct level. The selections are 12V, 24V or 32V and should be set to the
voltage specified for your drive unit.
Note !
Selection of improper voltage level for your drive unit may damage both the
drive unit and junction unit even if the protection circuits in the junction unit
are activated.
Refer to the drive unit table on page 51 for information. It is not possible to
select a higher voltage than the input voltage. The CLUTCH/BYPASS
voltage is automatically set to the same as the drive unit voltage. In Rudder
Test, the AP35 system will also automatically detect whether the drive unit
is a reversible motor or solenoid operated.
To change the voltage selection, rotate the course selector.
Proceed to next menu item by pressing STBD [>] button.
74
INSTALLATION
Dockside
settings?
INSTALLATION
Boat type:
Displacement
INSTALLATION
Drive unit
voltage 12V
22083083H