Ri35 Mk2 Rudder Angle Indicator; Ri35 Mk2 Illumination; Zero Adjust; Figure 4-20 Ri35 Mk2-J3000X/J300X Wiring Diagram - Simrad AP35 Instruction Manual

Table of Contents

Advertisement

4.17 RI35 Mk2 Rudder Angle Indicator

The RI35 Mk2 is designed for flush, bulkhead or bracket mounting, and
should be positioned in a location in clear view of the helmsman. Mounting of
RI35 Mk2 is identical to the mounting of AP35 Control Unit; refer to page 54.
When the location is determined, the cables should be connected to RI35 Mk2
before the unit is mounted.
The interconnection cables are screened, and the screen should be grounded in
the autopilot junction unit. See Figure 4-20 for connections to the autopilot
junction unit.
Rudder
Feedb.
*

RI35 Mk2 illumination

Internal LED's illuminates the scale. The illumination is turned on and
adjusted in three steps by pushing the front panel keypad.

Zero adjust

Note !
Prior to making a zero adjustment on the indicator, make sure the feedback
unit is installed and aligned according to it's mounting instruction.
Follow the instructions on page 83 to zero adjust the rudder feedback.
Press and hold the illumination key for 5 seconds. The pointer will now
adjust itself to zero confirmed by a 1-second beep.
Note !
There may be a difference in the RI35 Mk2 and the autopilot reading. This is
normal because the autopilot zero adjust compensates for drag caused by
the hull, flaps etc. If you prefer the readings to be aligned, then put the
rudder amidships using the RI35 Mk2 as reference, and then zero adjust the
autopilot.
22083083H
J3000X/J300X/J300X-40
JUNCTION UNIT
MAIN PCB
DATABOX
(NMEA Input1)
*
*
RUDDER FEEDBACK

Figure 4-20 RI35 Mk2-J3000X/J300X Wiring diagram

RI35 Mk2
RU DDER AN GLE
IND ICATOR
N M E A
C U R R
F R E Q S U P P L Y
*
*
* Non polarized (colour independant)
RF300
UNIT
Installation
RI35 Mk2
RU DDER AN GLE
IND ICATOR
N M E A
C U R R
F R E Q S U P P L Y
61

Advertisement

Table of Contents
loading

Table of Contents