Cd100A Course Detector; Figure 4-31 Ci300X Connections - Simrad AP35 Instruction Manual

Table of Contents

Advertisement

For detailed information, see separate CI300X Manual.
CI300X COMPASS INTERFACE
Note !
CD100 has a connector that has to be cut off the cable.

4.30 CD100A Course Detector

On some installations the owner may prefer to use the boats own compass.
The compass must be fully gimballed and have a flat surface underneath to
fit the CD100A. Make hole for a 6 mm screw in the bottom of the compass
and mount the CD100A as shown on the drawing. Secure the 6 mm screw
through the centre hole of the CD100A. Make sure the cable does not
prevent the compass from moving freely in the gimbals.
22083083H
TB5
ALARM
OUTPUT
(Normally open)
TB4
ENAB
NON FOLLOW UP
PORT
STEERING
STBD
LEVER
COM
TB3
S3
S2
S1
R2
R1
TB2
GND
COS
SIN
TB1
4
COS
5
SIN
3
Vref
1
LO
2
HI

Figure 4-31 CI300X connections

ROBNET
CONNECTIONS
RGC10/RGC50
GYRO COMPASS
FLUXGATE COMPASS
WITH SINE/COSINE
OUTPUT
MAGNETIC COMPASS
WITH CD100A COURSE
DETECTOR
ALT. 2
BLUE
COS
BLACK**
SIN
GREEN
Vref
ORANGE
LO
BLACK*
HI
Installation
DC SUPPLY
CD100 CONNECTIONS:
ALT. 1
GREY
COS
YELLOW
SIN
GREEN
Vref
WHITE
LO
BROWN
HI
To identify the black wires,
measure 8-12 ohm between
orange and black* and 6-10
ohm between green and
black**.
Third black wire not in use.