3.24
Photo Interrupter
(1) Disconnect the connector, and remove the photo interrupter.
Connector
3.25
T1 Solenoid ASSY / MP Solenoid ASSY
(1) Remove the two cup S M3x6 Taptite screws, and remove the feeding gear plate unit.
(2) Remove the spring.
(3) Remove the two cup S M3x6 Taptite screws, and remove the solenoid holder.
Taptite, cup S
M3x6
Feeding gear plate unit
Photo interrupter
Fig. 4-71
Spring
Fig. 4-72
4-39
HL-6050/6050D/6050DN SERVICE MANUAL
Solenoid holder
Taptite, cup S M3x6