(20) C0F32: ATDC Sensor malfunction
C0F33: Abnormally low T/C as detected by ATDC Sensor
ATDC Sensor (UN2)
ATDC
C0F32, C0F33
Step
1
PJ7A on Master Board, CN10, and PJ7 on the
sensor are properly connected.
2
ATDC Sensor operation: the voltage across
PJ7A-10B on Master Board and GND changes
in the range between DC0.5V and DC4.5V dur-
ing a copy cycle.
Relevant Electrical Parts
CN10
1
1
PJ7
1
15
15
UN2
2
16
16
3
17
17
4
18
18
24
24
Check
T-66
Master Board (PWB-A)
PWB-A
PJ7A-8B(CONTROL)
PJ7A-9B(DC24V)
PJ7A-10B(OUT)
PJ7A-11B(GND)
4002C22TAA
Result
NO
Plug them in securely.
YES Change Master Board.
NO
Change sensor.
Action