WI 1185 6/03
EASY MENU DRIVEN PROGRAM MODE
DEALER PROGRAM - PRELIMINARY INFORMATION
!
Only Keypad #1 may be used for both Dealer and User programming, however this keypad may be located in any area.
!
The Master Security Code is printed on the panel's microprocessor can. Use this code to enter the Dealer Program Mode to program a
custom Dealer Security Code. Record the number, then remove the code label to prevent unauthorized access to the panel. If you forget
your Dealer Security Code, use the Master Security Code to enter programming.
!
After entering codes or data, press the save
!
If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.
!
Silence the sounder by the
!
A panel that has been COLD STARTED (Address Location 4093) performs identically to a new panel.
!
When programming a Multiple Area System, Direct Address Programming Mode must be used to complete the program.
KEYPAD #1: For ease of programming, it is recommended that a GEM-RP1CAe2 or GEM-K1CA be used as Keypad #1.
(Regardless of which keypad is selected, all new keypads are configured as Keypad #1 out of the box). If a GEM-RP2ASe2/
GEM-K2AS is used, configure address jumpers as Keypad #1 (see Configuring the GEM-RP2ASe2 Keypad, page 64).
ACCESSING DEALER PROGRAM MODE
1. Press
EEEEEE
2. Press "PRIOR/NO" button until "TURNON PROG Y/N" (GEM-RP2ASe2/
3. Press "NEXT/YES" button to Enter Dealer Program Mode.
4. Press
CC
CUSTOMIZING A DEFAULT PROGRAM
For new panels, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for:
•
Number of Zones in Area 1
•
Number of Zones in Area 2
•
Fire Zones in Area 1
•
2-Wire Fire Zones in Area 1
•
Local or Central Station Reporting System
•
Exit/Entry Zones in Area 1
•
Interior Zones in Area 1
•
24 Hour Zones in Area 1
•
Chime Zones in Area 1
•
Chime 2 Zones in Area 1
•
Exit/Entry2 Zones in Area 1
This procedure will automatically set up system keypads, EZMs, wireless transmitters, etc. After your basic default program has been
loaded, you may alter it as necessary in the Direct Address Program Mode.
NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by any
means, the number zones will be suppressed and cannot be changed. Should it be necessary to create a new custom default
program, (a) from the Dealer Program Mode, press the
4091 (Clear Program); (c) press the
L
NAPCO Security Systems
U
button. Data will not be stored into memory unless
G
button to continue, or by pressing the
Master Security Code
(on microshield)
GEM-K2AS) or "17" (GEM-RP3DGTL/GEM-K3DGTL or
GEM-RP4RFC/GEM-K4RF) appears on the LCD screen.
to exit Dealer Program Mode when finished.
•
50mS Loop Response Zones
required for Loop Response time in UL installations).
•
Aux Output Activated on Alarm Zones
•
Sensor Watch Zones
•
Keypad Sounder on Alarm Zones
•
Auto Bypass re-entry Zones
•
Enable no EOLR Zones
•
Number of Keypads in Area 1 and 2
•
Central Station Receiver 1 Tel. Number
•
Central Station Receiver 1 Account Number
•
Central Station Receiver 1 Format
•
Enter User Codes
C
U
button and start over.
C
button to exit.
R
•
RF Transmitter Points
(Note: 750mS is
•
Quick Method
•
Key Fob Transmitters
•
Enter Zone Descriptions
•
Dealer Code
•
Enable Telco Line Fault Test
•
Enable Burg Output Chirp on Keyfob
•
Enable CP-01
•
Clear Dealer Program
•
Cold Start
button to enter the Direct Address Program Mode; (b) access Location
X
GEM-P9600 Programming Instructions
!
Page 5
U
is pressed.
GEM-P3200
GEM-P9600
CONTROL
R
COMMUNCIATOR
MASTER SECURITY CODE
# - # - # - # - # - #