GEM-RP3DGTL/GEM-K3DGTL and GEM-RP4RFC/GEM-K4RF Keypad Easy Program Menu

To enter Dealer Program Mode, see page 5. Once entered, press
by pressing
). Press [NEXT] to enter Easy Program Mode. For the GEM-RP3DGTL/GEM-K3DGTL (and GEM-RP4RFC/GEM-K4RF),
B
questions are in the form of a 2-digit number flashing in the display. Press
Press
again to scroll through each segment. Press [NEXT] to go to the next question. To review your Easy Program Mode responses
R
U
(before pressing
to save), press
If the data is incorrect, press
R
sponses after the initial programming of the control, except for questions marked "For New Panel Only". These questions set up the basic struc-
ture of the panel program ("Number of Zones in an Area", etc.) and cannot be viewed or altered once set. To exit Dealer Program Mode, press
twice. To return the panel to the factory default, enter the Direct Address Program Mode, go to location 1198 and press
C
Flashing
01
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
02
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
04
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
05
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
06
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
07
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
X
GEM-P9600 Programming Instructions
R
until the 2-digit question number flashes in the display again. If the data is correct, press
R
to set the cursor into the next field and again enter your data. Note: Review your Easy Program Mode re-
Total Number of Zones in Area 1 (New Program Only)
Enter the total number of zones to be programmed for Area 1.
Valid entries are from 01 to 96. Directly enter the total number of zones, including leading zeros.
The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to
the next group of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press
save. Press the NEXT/YES button to proceed.
Total Number of Zones in Area 2 (New Program Only)
Programming Area 2 is identical to Area 1 above.
Press the NEXT/YES button to proceed.
Fire Zones in Area 1 (New Program Only)
Enter the zone number of any Fire Zones (including 2-wire, 4-wire or wireless).
Valid entries are from 01 to 96.
Directly enter each zone number, including leading zeros, and press
additional zone(s). Press the NEXT/YES button to proceed.
2-Wire Fire Zones in Area 1 (New Program Only)
Enter the zone number of any Fire Zone (from previous question) to be used with 2-wire smoke detectors.
Valid entries are 07 and 08. Directly enter each zone number, including leading zeros.
U
Press
to save, and repeat for any additional zone(s); press NEXT to proceed.
NOTE: Only zones which have been designated as Fire Zones can be programmed as 2 Wire Fire zones.
JP3 must be set to "2-WF" position for 2-wire fire. (refer to Installation Instructions).
Local or Central Station Reporting System (New Program Only)
Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for local system.
Exit/Entry Zones in Area 1 (New Program Only)
Enter the zone numbers of zones to be used as Exit/Entry zones.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: Exit/Entry Entry time of 30 seconds will automatically be programmed.
, followed by [PRIOR/NO] repeatedly until "17" is displayed (scroll back
to set the cursor into the next field to answer the question.
R
L
WI 1185 6/03
U
to save.