Rf Receivers & Supervisory Timer Options (Address 3776 & 3760-3775) - Gemini GEM-P9600 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

!
Page 56
RF RECEIVERS & SUPERVIS ORY TIMER OPTI ON S
ADDRESS 3776
Number of RF
LEFT
RIGHT
Receivers
blank (•)
Default for Number of Receivers
depends on Easy Menu Question for
RF Transmitters.
RF SUPERVISORY
RF TRANSMITTER
TIMER
Type 0
Window/Door, 2 Pt.
Type 1
Window/Door, 2 Pt.
Type 2
Window/Door, 2 Pt.
Type 3
Window/Door, 2 Pt.
Type 4
Window/Door, 4 Pt.
Type 5
Type 6
Type 7
Smoke Detector
[Default = blank (•) 8 from address 3760-3767 (80 minutes)]
RF SUPERVISORY TIMERS
DATA ENTRIES
DELAY
LEFT
RIGHT
blank (•) blank (•)
0 min.
blank (•)
1
10 min.
blank (•)
2
20 min.
blank (•)
3
30 min.
blank (•)
4
40 min.
blank (•)
5
50 min.
blank (•)
6
60 min.
blank (•)
7
70 min.
blank (•)
8
80 min.
blank (•)
9
90 min.
blank (•)
0
100 min.
blank (•)
B
110 min.
blank (•)
C
120 min.
blank (•)
D
130 min.
blank (•)
E
140 min.
blank (•)
F
150 min.
1
blank (•)
160 min.
1
1
170 min.
1
2
180 min.
1
3
190 min.
1
4
200 min.
1
5
210 min.
1
6
220 min.
1
7
230 min.
1
8
240 min.
1
9
250 min.
1
0
260 min.
1
B
270 min.
1
C
280 min.
1
D
290 min.
1
E
300 min.
1
F
310 min.
2
blank (•)
320 min.
2
1
330 min.
2
2
340 min.
2
3
350 min.
2
4
360 min.
2
5
370 min.
X
GEM-P9600 Programming Instructions
DATA ENTRIES
RIGHT
RF Receiver(s)
blank (•)
None
1
1
2
2
3
3
4
4
ADDRESS
3760-3767
LEFT
ADDR
RIGHT
3760
3761
3762
3763
3764
PIR
3765
PIR
3766
3767
RF SUPERVISORY TIMERS
DATA ENTRIES
DELAY
LEFT
RIGHT
2
6
380min.
2
7
390 min.
2
8
400 min.
2
9
410 min.
2
0
420 min.
2
B
430 min.
2
C
440 min.
2
D
450 min.
2
E
460 min.
2
F
470 min.
3
blank (•)
480 min.
3
1
490 min.
3
2
500 min.
3
3
510 min.
3
4
520 min.
3
5
530 min.
3
6
540 min.
3
7
550 min.
3
8
560 min.
3
9
570 min.
3
0
580 min.
3
B
590 min.
3
C
600 min.
3
D
610 min.
3
E
620 min.
3
F
630 min.
4
blank (•)
640 min.
4
1
650 min.
4
2
660 min.
4
3
670 min.
4
4
680 min.
4
5
690 min.
4
6
700 min.
2550 min. = 42
F
F
Hr., 30 min.
(A D DR ES S 3 7 7 6 & 37 6 0 -3 7 7 5 )
RF RECEIVERS: Up to 4 RF Receivers may be programmed.
NOTE: This adds wireless capability to the system, increasing
up to 96 the number of zones.
!
1. Select the number of receivers from the table shown.
!
2. Enter in corresponding right digit address location shown
(left digit is not used).
RF SUPERVISORY
RF TRANSMITTER
TIMER
Type 8
Smoke Detector
Type 9
Keyfob
Type A
Dual Tech.
Type B
Keyfob
Type C
Window/Door, 4 Pt.
Type D
PIR
Type E
Smoke Detector
Type F
Napco Glass Break
[Default = blank (•) 8 from address 3768-3775 (80 minutes)]
RF SUPERVISORY TIMERS: RF Supervisory Timers may be
programmed for each type of transmitter used. A transmitter will send a
transmission every time it is tripped, when there is NO activity, the
transmitter sends a status transmission about once an hour. If the
receiver does NOT receive ANY signal (a trip or a status) from a
transmitter in the time specified for transmitter type, a system trouble
"
E-04-NN
" will be displayed at the keypad.
!
1.
Select timer delay from the table shown.
programmed in increments of 10 minutes each. Valid entries are
(•)8-FF (80 minutes-2550 min) (2550 minutes = 42 hr,30 min).
WARNING: Timers have uncertainty of +/-30 minutes.
!
2.
Enter in corresponding address locations above (left and right
digits).
!
3.
For a desired timer not listed do the following:
6 Quotient
16 100
96
4 Remainder
A. Choose a desired timer (intervals of 10),
ex: 1440 min. (24 Hours)
B. Divide it by 10, ex: 1440/10 = 144
C. Divide it by 16
NOTE: These timers apply only to Supervised RF Transmitters (see
RF Transmitters in Easy Menu Driven Mode Programming).
WI 1185 6/03
ADDRESS
3768-3775
LEFT
ADDR
RIGHT
3768
3769
3770
3771
3772
3773
3774
3775
Left Digit
Right Digit
L
NAPCO Security Systems
Timers are

Advertisement

Table of Contents
loading

Table of Contents