Page 48
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Disable Fire Reset
1
(Area 5)
Disable Fire Reset
2
(Area 6)
Disable Fire Reset
4
(Area 7)
Disable Fire Reset
8
(Area 8)
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Enable Day Zone Watch
1
(Area 5)
Enable Day Zone Watch
2
(Area 6)
Enable Day Zone Watch
4
(Area 7)
Enable Day Zone Watch
8
(Area 8)
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
RESERVED
1
Lug E4 Armed Away Only
2
Disable Auto-Unbypass
4
on Disarming
Bypass
8
Faulted Zones
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Access Control (Panel)
1
on Aux. Output
Enable Burg. Output
2
Warning on Entry
Enable
4
Manager's Mode
Start Exit Delay
8
after Ringback
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Disable
1
Function-Mode Download
Disable
2
Callback Download
Disable Answering-
4
Machine Download
Disable Auto-Reset
8
on Day Zone
!
1. Select the desired option by circling
!
2. Add the data values (ex: 15=1+2+4+8) from the selected options.
!
3. Enter in address location (left and right digits).
NOTE: Dark shaded data value box shows option not available.
X
GEM-P9600 Programming Instructions
SYSTE M OPTION S (A DDRESS 2415-2419)
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
*
Do not enable on systems with "K Series" keypads.
ADDRESS 2415
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2416
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2417
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2418
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2419
RIGHT DIGIT (SUM
OF DATA VALUES)
"
the data values for each digit (left and right).
WI 1185 6/03
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Disable Fire Reset
1
(Area 1)
Disable Fire Reset
2
(Area 2)
Disable Fire Reset
4
(Area 3)
Disable Fire Reset
8
(Area 4)
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Enable Day Zone Watch
1
(Area 1)
Enable Day Zone Watch
2
(Area 2)
Enable Day Zone Watch
4
(Area 3)
Enable Day Zone Watch
8
(Area 4)
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Opening Report only
1
after Alarm Report
Closing Report only on
2
Cond. Closing (Auto-Byp.)
Include Sel./Grp. Bypass
4
in Cond. Closing Status
Status Report
8
(Auto-Byp. Zones on
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Auto Bell Test
1
on Arming
Auto Reset after
2
Burg. Output Timeout
Suppress "Bypass"
4
Reminder when Armed
RESERVED
8
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Interior 1
1
Normally Bypassed*
Enable
2
Exit-Delay Restart
Reset Day Zone with
4
Arm/Disarm Only
Enable Local Alarm on
8
First Zone "AND" Trip
L
NAPCO Security Systems