Key Fob Transmitters (As Zone Input Devices); Enter Zone Descriptions; Enter Date; Enter Time - Gemini GEM-P9600 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

WI 1185 6/03
Key Fob Transmitters as Zone Input Devices
(Refer to display above: press the PRIOR button to go backwards).
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point
2; A1 = point 3; A2 = point 4. Up to 96 key fobs (using 1 button) or 48 key fobs (using 2 buttons) or 28 key fobs
(using all 4 buttons) or any combination up to a maximum of 96 controlled zones can be assigned, providing
multiple wireless panic buttons on a system, each reporting to a Central Station or a pager and/or annunciating
on a keypad the key fob zone number with a description. To assign a key fob to a zone: program the key fob
as you would a transmitter, entering the key fob's ID code, check sum and point number at the appropriate
zone. The "Quick Method" is not allowed. The zone may be hardwired to an electrical sensor as well as as-
signed to a key fob (either one will activate the zone alarm output). NOTE: If assigning a key fob to a zone, the
"ON/OFF" buttons on the key fob will no longer arm/disarm the system. The key fob is converted to a "panic
only" device.
ZONE DESCRIPTIONS: GEM-RP2ASe2/GEM-K2AS cannot be used to enter the date or time or Zone Descriptions. To enter this
information, you must use the GEM-RP1CAe2 or GEM-K1CA Keypad (See WI777) or the Napco Quickloader Software.
33
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
rE
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
EXIT DEALER PROGRAM MODE: This completes the custom default program. Press
Mode for further programming or press
CLEAR PROGRAM:
Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press
the Address Program Mode; (b) access Location 4091 (Clear Program) or 4093 (Cold Start); (c) press
Dealer Program Mode. A "SYSTEM TROUBLE/E09-00 SERVICE" will occur. Press
Clear Dealer Program (Erases Dealer Program)
Use this feature to erase the Panel Program, while maintaining Scheduled Data and Zone Descriptions. Access address 4091 and press
not allowed. NOTE: Enter Easy Menu Driven Program Mode to reprogram system.
Cold Start (Erases Entire Program)
This erases all programmed data (Dealer Program, Zone Description Data and Schedules). Access address 4093 and press
allowed. NOTE: Some features (schedules) can only be programmed again with the Downloading Software.
L
NAPCO Security Systems

Dealer Code

Directly enter the Dealer Code (default = 456789), using 0 through 9 buttons.
U
Press
to save.
Re-enter the Dealer Code to verify the previous code.
U
Press
to save.
Press the NEXT/YES button to proceed.
once again to end all programming and resume normal keypad operation.
C
C
U
C
to silence the keypad.
X
GEM-P9600 Programming Instructions
Page 21
DATA
AUX 1/AUX 2 OPTIONS
ENTRY
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
3
Relay Group 3 Toggle
4
Relay Group 4 Toggle
5
Relay Group 5 Toggle
6
Relay Group 6 Toggle
7
Relay Group 7 Toggle
8
Relay Group 8 Toggle
9
Panic
A
Auxiliary
B
Instant
C
Aux. Output Toggle
D
Access on Aux. Output
E
Arm STAY
F
Interior Bypass
to enter the Direct Address Program
C
and then (d) press
C
to exit the
U
. Data entry is
U
. Data entry is not
!
to enter