Quick Links

HARDWIRE
CONTROL PANEL/COMMUNICATOR
GEMINI
SYSTEM ARMED
SYSTEM ARMED
01/01/00 12:00 AM
01/01/97 12:00AM
A
1 2
3
D
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
GEM-RP1CAe2
Quick Start:
1. Refer to the wiring diagram, connect the keypad(s), siren, aux. power, aux. output, remote bus, earth ground, zone and telephone
wiring. NOTE: See Installation Instructions (WI817).
2. Connect AC power first and then the battery.
3. Configure the keypad (see page 63).
4. Access the Easy Menu Driven (Dealer Program) Mode:
Press EEEEEE A
Press g Until "ACTIVATE PROGRAM Y/N" (GEM-RP1CAe2), "TURNON PROG Y/N" (GEM-RP2ASe2) or
"17"
Press F To Enter Dealer Program Mode (see page 6).
© Napco 2000
R
G E M - P 3 2 0 0
GEMINI
NEXT/YES
E
A
1 2
PRIOR/NO
F
B
4
AREA
G
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
R
Master Security Code
(on microshield)
(GEM-RP3DGTL) appears on the keypad display.
PROGRAMMING
INSTRUCTIONS
SYSTEM ARMED
READY
01/01/97 12:00AM
READY
AC ON
AC ON
NEXT/YES
3
E
D
PRIOR/NO
5 6
F
AREA
G
R
GEM-RP2ASe2
WIRELESS
GEMINI
SYSTEM ARMED
48
ENT A1
01/01/97 12:00AM
INTERIOR
BYPASS
FIRE/TBL
SYS TBL
A
1 2
3
D
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
GEM-RP3DGTL
WI818D 8/00
CHIME
NEXT/YES
E
PRIOR/NO
F
AREA
G
R

Advertisement

Table of Contents
loading

Summary of Contents for Gemini GEM-P3200

  • Page 1 Press EEEEEE A Master Security Code (on microshield) Press g Until “ACTIVATE PROGRAM Y/N” (GEM-RP1CAe2), “TURNON PROG Y/N” (GEM-RP2ASe2) or “17” (GEM-RP3DGTL) appears on the keypad display. Press F To Enter Dealer Program Mode (see page 6). © Napco 2000 WI818D 8/00...
  • Page 2 Version 18 (or greater) PCBoard. Do NOT attempt to upgrade a GEM-P3200 control panel which currently is running Firmware Version 11C (or prior) to version 20 (or greater) by replacing the EPROM. The PCBoard version ( triangle number) is printed on a triangular shaped sticker affixed to the GEM-P3200 circuit board. NAPCO Security Systems, Inc.
  • Page 3: Table Of Contents

    Direct Address Programming Example....33 GEM-P3200 WIRING DIAGRAM ........75 Refer to accompanying GEM-P3200 Installation Instructions (WI817) for installation information. NOTE: THESE INSTRUCTIONS ARE INTENDED AND WRITTEN FOR PROFESSIONAL INSTALLATION PERSONNEL HAVING SUITABLE TRAINING, EXPERIENCE AND INSTALLATION EQUIPMENT. IT IS RECOMMENDED THAT AFTER PROGRAMMING, THE ERROR CHECK UTILITY OF THE PCD3000 DOWNLOADER BE USED TO VERIFY THAT THE CONTROL PANEL PROGRAM CONTAINS NO ERRORS OR CONFLICTS WHICH MAY INHIBIT ITS INTENDED OPERATION.
  • Page 4: System Programming Options

    SYSTEM PROGRAMMING OPTIONS INTRODUCTION The GEM-P3200 control panel may be programmed by various means, each of which will be covered in detail in the sections that follow. Keypad displays shown first are for a GEM-RP1CAe2 (Version 6), the recommended keypad for programming, then for the GEM-RP2ASe2.
  • Page 5: Easy Menu Driven Program Mode

    Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the button to enter the Direct Address Program Mode; (b) access Location 4091 (Clear Program); (c) press the J button and start over. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 6: Gem-Rp1Cae2 Keypad

    ) button to proceed. Note: The GEM-P3200 is limited to a combined maximum of 48 zones and 7 keypads. All 48 zones and 7 keypads may be programmed in the EZ Program Mode. For more options, see Zone and Keypad Options in Direct Address Programming.
  • Page 7: Central Station Receiver 1 Tel. Number

    F 0 7 1 5 1 6 8 4 2 9 4 0 0 Go to Central Phone # input screen and press: [*] [5] [0] [7] [1] [5] [1] [6] [8] [4] [2] [9] [4] [0] [0] [ON/OFF] NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 8: Central Station Receiver 1 Format

    Sescoa, Vertex, DCI, Franklin Radionics Modem 2 in Direct Address Programming. See CS Fast Radionics Fast Receiver Options. Ademco Point ID Silent Knight Fast Ademco Express Radionics, DCI, Franklin Slow Pager Universal High Speed Radionics BFSK NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 9: Enter User Codes

    ARM ONLY LEVEL 3 ARM ONLY NONE SERVICE LEVEL 1 SERVICE LEVEL 2 SERVICE LEVEL 3 SERVICE Note: “Y” indicates option is enabled. Note: “Y” indicates option is enabled. Note: “Y” indicates option is enabled. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 10 CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press to save. Similarly, to cancel a code, blank out each number of the code and press to save to save. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 11: Rf Transmitter Points

    Press NEXT ( ) button to proceed. Quick Method. If a receiver is already installed in the panel, Napco Z N # X M I T # + C S P transmitter wireless points can be programmed automatically (“enrolled”) using the following procedure.
  • Page 12: Key Fob Transmitters

    Zone Number (e.g. “01”) and change the Zone Number using the buttons. Program a new description as above. NOTE: Zone Descriptions can only be entered through the GEM-/RP1CAe2 Keypad or by using the Napco Quickloader Software. Press NEXT ( ) button to proceed.
  • Page 13: Enter Time

    GEM-RP1CAe2 Keypad and Foreign Language configuration(similar to a new panel). Access address 4093, then press the button. Data entry is not allowed. NOTE: Some features (schedules) can only be programmed again with the Downloading Software. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 14: Gem-Rp2Ase2 Keypad

    ) button to proceed. ENT A2 Note: The GEM-P3200 is limited to a combined maximum of 48 zones and 7 keypads. All 48 zones and 7 keypads may be programmed in the EZ Program Mode. For more options, see Zone and Keypad Options in Direct Address Programming.
  • Page 15: Local Or Central Station Reporting System

    01 to 07. Directly enter the number of keypads, including leading zeros. Use number buttons through . NOTE: Press button for a zero. Press to save . Press NEXT ( ) button #KP 00 to proceed. (Direct Entry) NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 16: Central Station Receiver 1 Tel. Number

    Direct Address Programming. See CS Receiver Options. Radionics Fast Silent Knight Fast Radionics, DCI, Franklin Slow Universal High Speed Radionics BFSK FBI 4/3/1 Radionics Modem 2 Ademco Point ID Ademco Express Pager NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 17: Enter User Codes

    ARM ONLY LEVEL 3 ARM ONLY NONE SERVICE LEVEL 1 SERVICE LEVEL 2 SERVICE LEVEL 3 SERVICE Note: “Y” indicates option is enabled. Note: “Y” indicates option is enabled. Note: “Y” indicates option is enabled. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 18 CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press to save. Similarly, to cancel a code, blank out each number of the code, press to save. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 19: Rf Transmitter Points

    :0 PT0 to save. Press NEXT ( ) button to proceed. Quick Method. If a receiver is already installed in the panel, Napco (Direct Entry) transmitter wireless points can be programmed automatically (“enrolled”) using the following procedure. NOTE: The transmitter point will be enrolled ZN#11 only if the signal strength is 3 or greater.
  • Page 20: Key Fob Transmitters

    “ON/OFF” buttons on the key fob will no longer arm/disarm the system. The key fob is converted to a “panic only” device. ZONE DESCRIPTIONS: GEM-RP2ASe2 cannot be used to enter Zone Descriptions. To enter Zone Descriptions you must use the GEM-RP1CAe2 Keypad or the Napco Quickloader Software. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 21: Enter Date

    Address Program Mode; (b) access Location 4091 (Clear Program) or 4093 (Cold Start); (c) press and then (d) press the button to exit the Dealer Program Mode. A System Trouble Condition will occur. Press the button to silence the keypad. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 22: Gem-Rp3Dgtl Keypad

    20 zones. Press to save. Press NEXT (Direct Entry) ) button to proceed. Note: The GEM-P3200 is limited to a combined maximum of 48 zones and 7 keypads. All 48 zones and 7 keypads may be programmed in the EZ BYPASS FIRE/TBL...
  • Page 23 Press NEXT ( ) to proceed. BYPASS FIRE/TBL SYS TBL CHIME INTERIOR (Direct Entry) NOTE: Central Station Receiver 2 and 3 Telephone Numbers can only be entered in Direct Address Programming. See CS Receiver Options. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 24 Sescoa, Vertex, DCI, Franklin Radionics Modem 2 in Direct Address Programming. See CS Fast Radionics Fast Receiver Options. Ademco Point ID Silent Knight Fast Ademco Express Radionics, DCI, Franklin Slow Pager Universal High Speed Radionics BFSK NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 25 ARM ONLY LEVEL 3 ARM ONLY NONE SERVICE LEVEL 1 SERVICE LEVEL 2 SERVICE LEVEL 3 SERVICE Note: “Y” indicates option is enabled. Note: “Y” indicates option is enabled. Note: “Y” indicates option is enabled. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 26 CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press to save. Similarly, to cancel a code, blank out each number of the code press to save to save. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 27 Press NEXT ( ) button to proceed. Quick Method. If a receiver is already installed in the panel, Napco transmitter wireless points can be programmed automatically (“enrolled”) using the following procedure. NOTE: The transmitter point will be enrolled only if the signal strength is 3 or greater.
  • Page 28 Address Program Mode; (b) access Location 4091 (Clear Program) or 4093 (Cold Start); (c) press and then (d) press the button to exit the Dealer Program Mode. A System Trouble Condition will occur. Press the button to silence the keypad. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 29: Direct Address Program Mode

    “TURNON PROG Y/N” (GEM-RP2ASe2) or “17” (GEM-RP3DGTL) appears on the keypad display. 3. Press F To Enter Dealer Program Mode 4. Press C To Exit Easy Menu Driven Program Mode & Enter Direct Address Program Mode NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 30: What You See On The Keypad

    = DATA ENTRY LOCATION (Left and Right Digits) DIRECT ADDRESS PROGRAM MODE KEYPAD COMMANDS A. GEM-RP1CAe2 Keypads 0 0 0 0 3 C ( S E C O N D S ) 0000 3C NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 31 COMPUTERIZED SECURITY SYSTEM To exit, press the C button NOTE: “A” = ; “B” = ; “C” = ; “D” = ; “E” = ; “F” = . Press for a zero or to clear. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 32: Programming Overview

    It is blank • recommended that the panel be uploaded to NAPCO's Quickloader software following any keypad programming and that the PCD3000's error-check feature be utilized to reduce the possibility of programming omissions or "...
  • Page 33: Direct Address Programming Example

    1 2 1 8 will advance to the data field. 5. Press to enter an “E” in the left digit and press to enter a blank (•) in the right digit. 6. Press to save. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 34: Programming Options & Worksheets

    Determining data entry for a location (each “nibble”). Numbers in parentheses indicate data for selected zones or features. (See Programming Worksheets that follow.) DEFAULTS: The defaults shown on the following pages are automatically set after exiting the Easy Menu Driven Mode. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 35: System Delays (Addr 0000-0002, 2402, 2406 & 2414)

    A. Choose a desired delay/timeout , ex: 20. Note: For Sensor Watch only divide it by 10, ex: 20/10 = 2 1 Quotient Left Digit B. Divide it by 16 16 20 4 Remainder Right Digit NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 36: System Delays (Addr 2400, 2401, 2403-2405 & 4083)

    DEALER SECURITY CODE: Enter up to 6 digits to be used by the dealer to enter programming. 1. Enter in both left and right digits of address locations. 2. Valid entries are: 0-9. Note: If left blank, the Master Security Code must then be used to enter programming. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 37: Cs Receiver Opt

    (left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 38: Cs Receiver Tel. Numbers (Addr 0527-0546, 0552-0571, 0577-0596)

    1. Enter in right digit only (left digit is not used). 2. Valid entries are: 0-9. 2. Valid entries are: 1 or 2. Note: Download Security Code must match the code entered in the PCD3000 Software. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 39: Cs Subscriber Id Numbers (Addr 0650-0857)

    CS TELCO 2 SUBSCRIBER EVENT ID NUMBERS (BACKUP REPORTING) AREA 1 AREA 2 SYSTEM ADDRESS 0752-0755 ADDRESS 0756-0759 ADDRESS 0784-0787 (RIGHT DIGITS 1-4) (RIGHT DIGITS 1-4) (RIGHT DIGITS 1-4) 0752 0753 0754 0755 0756 0757 0758 0759 0784 0785 0786 0787 NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 40: Cs Reporting Codes (Addr 0860-0869)

    Opening after Alarm blank (•) 0862 blank (•) 0867 NOTE: Dark shaded data value box Fail to Close 0868 shows option not available. [Default = blank (•) blank (•) from address 0859-0869] Fail to Open 0869 NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 41: Cs Reporting Codes (Addr 0870-0904)

    Leave blank (•) to select Rotary Dialing. 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 42: Cs Zone Reporting Codes (Addr 0910-0957)

    MODEM CODES determine the zone types reported for the following formats: SIA and ADEMCO Point Hold up Gas Alarm 1. Select the desired Modem Code for each zone from the table shown. Heat Alarm Auxiliary Alarm 24 Hour Auxiliary NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 43: Cs User Reporting Codes (Addr 1030-1081)

    User 98 = Quickloader Arming/Disarming LEFT RIGHT Telco 1 1-8 (see Easy Menu Program Driven User 99 = Easy Arming (Opening not applicable) Mode) will report as Users 25-32, blank (•) User 00 = Keyswitch Arming respectively. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 44 User 98 = Quickloader Arming/Disarming LEFT RIGHT Telco 3 1-8 (see Easy Menu Program Driven User 99 = Easy Arming (Opening not applicable) Mode) will report as Users 25-32, blank (•) User 00 = Keyswitch Arming respectively. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 45 (left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 46: Global System Trbl. Reporting Opt. (Addr 1082-1116)45 Area System Trbl. Reporting Opt. (Addr 1120-1137)

    [Default = blank (•) blank (•) from address 1130-1137] 1. Select the desired option by circling " the data values for 2. Add the data values (ex: 15=1+2+4+8) from the selected each digit (left and right). options. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 47: Zones 1-48 Options (Addr 1200-1786)

    Zone ANDing Group 2 1355 1255 Interior #1 Bypass 1362 1262 Keypad Sounder on Alarm 1364 1264 Fire (C) 1375 1275 Fire Alarm Verification (C) 1376 1276 Chime 2 1386 1286 See Zone Options on Page 50. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 48 Zone ANDing Group 2 1455 1562 Interior #1 Bypass 1462 1564 Keypad Sounder on Alarm 1464 1575 Fire (C) 1475 Fire Alarm Verification (C) 1576 1476 Chime 2 1586 1486 See Zone Options on Page 50. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 49 Zone ANDing Group 2 1755 1655 Interior #1 Bypass 1762 1662 Keypad Sounder on Alarm 1764 1664 Fire (C) 1775 1675 Fire Alarm Verification (C) 1776 1676 Chime 2 1786 1686 See Zone Options on Page 50. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 50 Fire, Pulse Alarm Output and Fire Verification is enabled for the zone numbers entered in “FIRE ZONES” Menu Driven program Mode. 2-Wire Smoke Detector is enabled for zone numbers entered in “2 WIRE FIRE ZONES” NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 51: System Options (Addr 2415-2419)

    (left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 52: System Options (Addr 2420-2422 & 4084)

    NOTE: Dark shaded data value box shows option not available. ADDRESS ALARM/TROUBLE 3879-3881 REPORTING CODES LEFT ADDR RIGHT Wireless Low Battery blank (•) 3879 Wireless Supervisory blank (•) 3880 Wireless Tamper blank (•) 3881 [Default = blank (•) blank (•) from address 3879-3881] NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 53 OF DATA VALUES) OF DATA VALUES) Note: Right digit is RESERVED RESERVED (not used). Enter data in left digit blank (•) RESERVED only. Disable Auto [Default = blank (•) blank (•)] Dial Tone Detection NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 54: Keypad Options (Addr 2425-2454)

    (left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 55: User Area Options (Addr 2500-2547)

    4 2 1 blank (•) 2500 NOTE: No circle = feature disabled. 4 2 1 4 2 1 ZN04 ZN03 ZN02 ZN01 4 2 1 4 2 1 Draw Circle 4 2 1 NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 56: Ezm Group Options (Addr 2600-2627)

    2. Enable desired options for each area by drawing a circle " around its corresponding binary data value. NOTE: No circle = feature disabled. 3. Enter data in corresponding left and right digit address locations above. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 57: Area Arming Options (Addr 2650-2651)

    (left and right). 2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 58: Area Output Control Options (Addr 2700-2733)

    2. Add the data values (ex: 15=1+2+4+8) from the selected options. 3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 59: Rf Rcvrs. & Sup. Timers (Addr 3776 & 3760-3775)

    870 min. 2010 min. 900 min. 2040 min. 930 min. 2070 min. blank (•) 960 min. 2100 min. 990 min. 1020 min. 1050 min. 7650 min. = 127 Hr., 30 min. 1080 min. 1110 min. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 60: System Reset Features (Addr 4091-4093)

    4093XX Access address 4093, then press the button. Data entry is not allowed. GEM-RP2ASe2 Keypad NOTE: Some features (schedules, language configuration) can only be re-programmed with the Downloading Software. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 61: User Program Mode

    G 0 button to clear character at cursor. NOTE: Press number buttons. The cursor will then To continue press E or F button. advance to the User Code and read the existing code, if any. Programming User Codes NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 62: Zone Descriptions

    Press the button to save. Advance to the next zone as in Steps 1 and 2 above and repeat this procedure until all zones have been programmed. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 63: Keypad Configuration Mode

    A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep. 2. Press the button to continue or press the button to exit. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 64 Press the button to continue or press the button to exit the Keypad Configuration Mode (display will read 01 OUT OF SYSTEM “ ”). Then replace Jumper JP5 across Pins 1–2 (top two). NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 65 Cut Jumper B to disable LCD backlighting. DISABLE SOUNDER Cut Jumper C to disable the sounder. (Do not disable in UL applications.) NAPCO Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com...
  • Page 66: Keypad Programming Modes

    Level 3 code with appropriate option Requires dealer code DISPLAY AUTO ARM SCHD Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads ACTIVATE PROGRAM Initial Configuration only; suppressed thereafter ACTIVATE DOWNLOAD DISPLAY RF XMITTER STAT RELAY CONTROL NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 67 ACTIVATE DOWNLOAD DISPLAY RF XMITTER STAT Minimum level required to access function RELAY CONTROL Level 3 code with appropriate option Requires dealer code Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads Initial Configuration only; suppressed thereafter NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 68 ENTER DATE (MM/DD/YY) ENTER TIME (HH:MMA/P) ENTER DEALER CODE Minimum level required to access function Level 3 code with appropriate option Requires dealer code Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads Initial Configuration only; suppressed thereafter NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 69 RELAY CONTROL Press button (at any time) Minimum level required to access function Level 3 code with appropriate option Requires dealer code Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads Initial Configuration only; suppressed thereafter NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 70: Keypad Configuration Mode

    Return Jumper JP5 * from Pins 2-3 to Pins 1-2 (“SYSTEM READY”) * JP5 is located at the top-right corner of the circuit board. ** If a Compatibility Number other than “0000” is programmed, “OLD COMPAT# XXXX” is displayed. NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 71: Programming Options Index

    CS Receiver 1 Options Direct Address 0526 CS Receiver 1 Telephone Number Direct Address 0527-0546 CS Receiver 2 Format Direct Address 0550 CS Receiver 2 Options Direct Address 0551 CS Receiver 2 Telephone Number Direct Address 0552-0571 NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 72 Entry Delay 2 Direct Address 0002 Entry/Exit 1 (Zone Option) Direct Address 1216, 1316, 1416 & 1516 47 - 49 Entry/Exit 2 (Zone Option) Direct Address 1217, 1317, 1417 & 1517 47 - 49 NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 73 RF Transmitter Points Easy Menu Driven RF Trouble Report Code Direct Address 0897 Selective Bypass (Zone Option) Direct Address 1205, 1305, 1405, . . ., 2305 47 - 49 Sensor Watch Report Code Direct Address 0877 NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 74 1245, 1345, 1445, . . ., 2345 47 - 49 Zone Options - Zones 1 To 96 Direct Address 1200-2376 47 - 49 Zones Report Code - Zones 1 to 96 Direct Address 0910-1005 NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 75: Gem-P3200 Wiring Diagram

    WI818D 8/00 Page 75 GEM-P3200 WIRING DIAGRAM NAPCO Security Systems GEM-P3200 Programming Instructions...
  • Page 76 In order to exercise the warranty, the product must be returned by NAPCO is not an insurer of either the property or safety of the security professional, shipping costs prepaid and the user's family or employees, and limits its liability for insured to NAPCO.