External Relay Control / Relays 79-96 (Address 3856-3873 & 3112-3183) - Gemini GEM-P9600 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

WI 1185 6/03
EXTERNAL R ELAY CONTR OL / R ELAYS 79-9 6
(RELAY/entry 79)
ADDRESS 3856 & 3112-3115
3856
3112
3113
3114
L
R
L
R
L
R
L
R
(RELAY/entry 82)
ADDRESS 3859 & 3124-3127
3859
3124
3125
3126
L
R
L
R
L
R
L
R
(RELAY/entry 85)
ADDRESS 3862 & 3136-3139
3862
3136
3137
3138
L
R
L
R
L
R
L
R
(RELAY/entry 88)
ADDRESS 3865 & 3148-3151
3865
3148
3149
3150
L
R
L
R
L
R
L
R
(RELAY/entry 91)
ADDRESS 3868 & 3160-3163
3868
3160
3161
3162
L
R
L
R
L
R
L
R
(RELAY/entry 94)
ADDRESS 3871 & 3172-3175
3871
3172
3173
3174
L
R
L
R
L
R
L
R
[Default = blank (•) blank (•) from address 3778-3873 & 2800-3183]
To program, follow the 5 steps below:
STEP 1: RELAY # OPTIONS:
96 available external relays from Relay Module RM3008. Multiple entries can
drive the same External Relay.
!
Select the relay number from Table 1 (shown on next page); enter in
corresponding left and right digit address locations.
Note: Entries 01-96 correspond to relays 1 through 96. If entries are zero, zero
(00), then relay number is identical to the relay/entry address table number, in the
selected address table(s) above.
STEP 2: AREA OPTIONS:
Each relay/entry can be assigned to Area 1-8 or all areas.
!
Select the area from Table 2 (shown on next page); enter in corresponding left and right digit
address locations.
STEP 3: TIMEOUTS:
Each relay event can be assigned a timeout depending on Alarm Type option.
!
If Alarm Type (see next page) is selected for timeout in minutes or seconds, select the timeout from Table
3 (shown on next page) in minutes or seconds and enter in corresponding address location (left digit and
right digits). To choose seconds or minutes, see step 5A below. 254 is maximum entry.
STEP 4: EVENT ID CODES:
!
Select 2-digit Event ID from Table 4 (see page 59); enter in corresponding address locations (left and right digit).
STEP 5: RELAY EVENT CONDITION OPTIONS:
condition; also, select a timeout type for each.
!
5A. Select Alarm Type and Timeout Type from Table 5A (see page 60); enter in corresponding address location (left digit).
NOTE: Select Timeout from Step 3.
!
5B. Select Activation from from Table 5B (see page 60); enter in corresponding address location (right digit).
L
NAPCO Security Systems
ADDRESS 3857 & 3116-3119
3115
3857
3116
L
R
L
R
L
ADDRESS 3860 & 3128-3131
3127
3860
3128
L
R
L
R
L
ADDRESS 3863 & 3140-3143
3139
3863
3140
L
R
L
R
L
ADDRESS 3866 & 3152-3155
3151
3866
3152
L
R
L
R
L
ADDRESS 3869 & 3164-3167
3163
3869
3164
L
R
L
R
L
ADDRESS 3872 & 3176-3179
3175
3872
3176
L
R
L
R
L
Each relay/entry can be assigned to any of the
Each relay event can be assigned any of the available event IDs from the table.
Each relay event can be assigned an alarm type; and an activation
( A D D R ES S 3 8 5 6 -3 8 7 3 & 3 1 1 2 - 31 8 3 )
(RELAY/entry 80)
3117
3118
3119
R
L
R
L
R
L
R
(RELAY/entry 83)
3129
3130
3131
R
L
R
L
R
L
R
(RELAY/entry 86)
3141
3142
3143
R
L
R
L
R
L
R
(RELAY entry 89)
3153
3154
3155
R
L
R
L
R
L
R
(RELAY/entry 92)
3165
3166
3167
R
L
R
L
R
L
R
(RELAY/entry 95)
3177
3178
3179
R
L
R
L
R
L
R
RELAY # AREA
L
(•)
Step
X
GEM-P9600 Programming Instructions
(RELAY/entry 81)
ADDRESS 3858 & 3120-3123
3858
3120
3121
3122
L
R
L
R
L
R
L
(RELAY/entry 84)
ADDRESS 3861 & 3132-3135
3861
3132
3133
3134
L
R
L
R
L
R
L
(RELAY/entry 87)
ADDRESS 3864 & 3144-3147
3864
3144
3145
3146
L
R
L
R
L
R
L
(RELAY/entry 90)
ADDRESS 3867 & 3156-3159
3867
3156
3157
3158
L
R
L
R
L
R
L
(RELAY/entry 93)
ADDRESS 3870 & 3168-3171
3870
3168
3169
3170
L
R
L
R
L
R
L
(RELAY/entry 96)
ADDRESS 3873 & 3180-3183
3873
3180
3181
3182
L
R
L
R
L
R
L
RELAY EVENT OPTIONS
Timeout Event ID
COND.
R
L
R
L
R
L
R
L
(•)
Step
Step
Step
Step
1
2
3
4
Continued
!
Page 59
3123
R
L
R
3135
R
L
R
3147
R
L
R
3159
R
L
R
3171
R
L
R
3183
R
L
R
R
5

Advertisement

Table of Contents
loading

Table of Contents