Page 46
ZONE OPTI ON S / ZON E S 1-96 (AD D RESS 1200-2386)
!
!
1. Select the desired
zone option.
ZONE OPTIONS
50ms Loop Response
NOTE: No circle = feature
10ms Loop Response
disabled.
Priority
Priority with Bypass
Auto-Bypass
NOTES:
(A) 50ms & 20 ms Loop Response only available for zones 1-8.
(B) 2-wire Smoke Detectors only available for zones 1-8.
(C) If Fire Alarm Verification is selected, then Fire must also be selected.
DEFAULTS: The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.
!
Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown, Zone Area 1 and Zone Area 2 are
enabled for the total number of zones entered in
!
Alarm Telco 1 is enabled for the zones if [YES] is entered for "REPORT ALL ZONES TO CENTRAL ZONES? Y/N".
!
Entry/Exit 1 and Chime are enabled for zone numbers entered in
!
Exit/Entry Follower and Interior Bypass are enabled for zone numbers entered in
!
Fire, Pulse Alarm Output and Fire Verification is enabled for the zone numbers entered in
!
2-Wire Smoke Detector is enabled for zone numbers entered in
X
GEM-P9600 Programming Instructions
2. Enable desired options
for each zone by drawing a
circle
around
its
"
corresponding binary data
value.
ZN04 ZN03 ZN02 ZN01
8
4
2
1
Draw Circle
"AREA 1 # ZONES = 08" and "AREA 2 # ZONES = 00"
!
3. Search table below
for data entry.
DIGIT VALUE DATA ENTRY
DIGIT VALUE DATA ENTRY
.
8
4
2 1
Blank (
)
8
4 2 1
8
4
2 1
1
8
4 2 1
8
4
2 1
2
8
4 2 1
3
8
4
2
1
8
4
2
1
4
8
8
4
2 1
4 2 1
8
4
2 1
5
8
4 2 1
6
8
4
2 1
8
4 2 1
7
8
8
4
2 1
4 2 1
.
"EXIT / ENTRY ZONES "
"INTERIOR ZONES"
"FIRE ZONES"
.
"2 WIRE FIRE ZONES"
WI 1185 6/03
!
4.
Enter
data
locations (left and right digits).
ADDRESS LOCATION
L
ADDR
8
blank (•)
1200
9
NOTE: Dark shaded data value box
0
shows option not available.
B
C
NOTE: See Direct Address
D
Programming
Example
E
page 22.
F
.
.
.
Note: See "Number of Zones
& Keypads per Area" in Easy
Menu Driven program Mode.
L
NAPCO Security Systems
in
address
R
1
on

Advertisement