Key Fob Transmitters (As Zone Input Devices); Enter Zone Descriptions; Enter Date; Enter Time - Gemini GEM-P9600 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

WI 1185 6/03
Key Fob Transmitters as Zone Input Devices
(Refer to display above: press the PRIOR button to go backwards).
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point
2; A1 = point 3; A2 = point 4. Up to 96 key fobs (using 1 button) or 48 key fobs (using 2 buttons) or 28 key fobs
(using all 4 buttons) or any combination up to a maximum of 96 controlled zones can be assigned, providing
multiple wireless panic buttons on a system, each reporting to a Central Station or a pager and/or annunciating
on a keypad the key fob zone number with a description. To assign a key fob to a zone: program the key fob
as you would a transmitter, entering the key fob's ID code, check sum and point number at the appropriate
zone. The "Quick Method" is not allowed. The zone may be hardwired to an electrical sensor as well as as-
signed to a key fob (either one will activate the zone alarm output). NOTE: If assigning a key fob to a zone, the
"ON/OFF" buttons on the key fob will no longer arm/disarm the system. The key fob is converted to a "panic
only" device.
ZONE DESCRIPTIONS: GEM-RP2ASe2/GEM-K2AS cannot be used to enter Zone Descriptions. To enter Zone Descriptions, you
must use the GEM-RP1CAe2/GEM-K1CA Keypad (See WI777) or the PCD-Windows Quickloader Software.

Enter Date

(
/
/
)
(Direct Entry)

Enter Time

(
:
)
(Direct Entry)
D e a l e r C o d e
4 5 6 7 8 9
D E A L E R C O D E
R E - E N T E R
EXIT DEALER PROGRAM MODE: This completes the custom default program. Press
Mode for further programming or press
CLEAR PROGRAM:
Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press
the Address Program Mode; (b) access Location 4091 (Clear Program) or 1093 (Cold Start); (c) press
4 0 9 1 X X
4 0 9 3 X X
L
NAPCO Security Systems
Enter Date (Press
R
Enter the current date in the format MM/DD/YY. (MM = month, DD = day and YY = year.
U
Press
to save. Press the NEXT/YES button to proceed.
Enter Time (Press
R
Enter the current time in format HH:MMA/P, where HH=hours (01–12); MM=minutes (00–59).
Select AM or PM by pressing any number button.
U
Press
to save. Press the NEXT/YES button to proceed.

Dealer Code

Directly enter the Dealer Code (default = 456789), using 0 through 9 buttons.
U
Press
to save.
Re-enter the Dealer Code to verify the previous code.
U
Press
to save.
Press the NEXT/YES button to proceed.
once again to end all programming and resume normal keypad operation.
C
Dealer Program Mode. A "SYSTEM TROUBLE/E09-00 SERVICE" will occur. Press
Clear Dealer Program (Erases Dealer Program)
Use this feature to erase the Panel Program, while maintaining Scheduled Data and Zone Descriptions. Access
H
address 4091 and press
to reprogram system.
Cold Start (Erases Entire Program)
H
This erases all programmed data (Dealer Program, Zone Description Data and Schedules). Access ad-
U
dress 4093 and press
grammed again with the Downloading Software.
to set cursor).
to set cursor.)
C
U
. Data entry is not allowed. NOTE: Enter Easy Menu Driven Program Mode
. Data entry is not allowed. NOTE: Some features (schedules) can only be pro-
X
GEM-P9600 Programming Instructions
Page 13
DATA
AUX 1/AUX 2 OPTIONS
ENTRY
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
3
Relay Group 3 Toggle
4
Relay Group 4 Toggle
5
Relay Group 5 Toggle
6
Relay Group 6 Toggle
7
Relay Group 7 Toggle
8
Relay Group 8 Toggle
9
Panic
A
Auxiliary
B
Instant
C
Aux. Output Toggle
D
Access on Aux. Output
E
Arm STAY
F
Interior Bypass
to enter the Direct Address Program
C
U
and then (d) press
C
to exit the
C
to silence the keypad.
!
to enter

Advertisement

Table of Contents
loading

Table of Contents