System Options (Addr 2415-2419) - Gemini GEM-P3200 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P3200:
Table of Contents

Advertisement

WI818D 8/00
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
RESERVED
1
RESERVED
2
RESERVED
4
RESERVED
8
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
RESERVED
1
RESERVED
2
RESERVED
4
RESERVED
8
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
RESERVED
1
Answering Machine P/U
2
W/O Line Seizure
Disable Auto-Unbypass
4
on Disarming
Bypass
8
Faulted Zones
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Access Control (Panel)
1
on Aux. Output
Enable Burg. Output
2
Warning on Entry
Enable
4
Manager's Mode
Start Exit Delay
8
after Ringback
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Disable
1
Function-Mode Download
Disable
2
Callback Download
Disable Answering-
4
Machine Download
Disable Auto-Reset
8
on Day Zone
!
1. Select the desired option by circling
!
2. Add the data values (ex: 15=1+2+4+8) from the selected options.
!
3. Enter in address location (left and right digits).
NOTE: Dark shaded data value box shows option not available.
L
NAPCO Security Systems
SYSTEM OPTIONS (ADDRESS 2415-2419)
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
blank (•)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
blank (•)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
ADDRESS 2415
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2416
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2417
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2418
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2419
RIGHT DIGIT (SUM
OF DATA VALUES)
"
the data values for each digit (left and right).
X
GEM-P3200 Programming Instructions
Page 51
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Disable Fire Reset
1
(Area 1)
Disable Fire Reset
2
(Area 2)
RESERVED
4
RESERVED
8
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Enable Day Zone Watch
1
(Area 1)
Enable Day Zone Watch
2
(Area 2)
RESERVED
4
RESERVED
8
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Opening Report only
1
after Alarm Report
Closing Report only on
2
Cond. Closing (Auto-Byp.)
Include Sel./Grp. Bypass
4
in Cond. Closing Status
Status Report
8
(Auto-Byp. Zones on Clos.)
RIGHT DATA
SYSTEM OPTIONS
VALUES
"
)
(CIRCLE
Auto Bell Test
1
on Arming
Auto Reset after
2
Burg. Output Timeout
Suppress "Bypass"
4
Reminder when Armed
RESERVED
8
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Interior 1
1
Normally Bypassed
Enable
2
Exit-Delay Restart
Reset Day Zone with
4
Arm/Disarm Only
Enable Local Alarm on
8
First Zone "AND" Trip
!

Advertisement