Page 22
B. GEM-RP3DGTL Keypad
Enter the Master Security Code (printed on microprocessor can) for a new panel or enter your custom
GEMINI
SYSTEM ARMED
Dealer Program Code if programmed. Press
1 7
ENT A1
01/01/97 12:00AM
INT ERIOR
BY PA SS
F IRE/T B L
SY S T BL
CHIM E
NEXT/YES
A
1 2
3
E
D
displayed. NOTE: If you pass Function "17", you can scroll back by pressing the
PRIOR/NO
B
4
5 6
F
AREA
C
7 8 9 0
G
YES (
E
COMPUTERIZED SECURITY SYSTEM
R
keypad. The questions will be in the form of a 2 digit number flashing in the digital display. Press the
button to
A
01
BYPASS
FIRE/TBL
INTERIOR
FIRE/TBL
INTERIOR
BYPASS
(Direct Entry)
02
BYPASS
FIRE/TBL
INTERIOR
FIRE/TBL
INTERIOR
BYPASS
(Direct Entry)
04
INTERIOR
BYPASS
FIRE/TBL
FIRE/TBL
INTERIOR
BYPASS
(Direct Entry)
05
INTERIOR
BYPASS
FIRE/TBL
BYPASS
FIRE/TBL
INTERIOR
(Direct Entry)
06
BYPASS
FIRE/TBL
INTERIOR
BYPASS
FIRE/TBL
INTERIOR
(Yes or No)
X
GEM-P3200 Programming Instructions
) to enter the Dealer Program Mode. The GEM-RP3DGTL is a dual 7-segment digital
scroll through each segment.
Flashing
Total Number of Zones in Area 1 & Area 2 (Appears for New Panel Only)
Directly enter the total number of zones to be programmed for Area 1 and
Area 2, respectively. Valid entries are from 01 to 48. Directly enter the total
SYS TBL
CHIME
number of zones, including leading zeros. Use number buttons
through
9
based on groups of 4 zones each (after the first 8 zones), and will
automatically round up to the next group of 4. For example, if you enter 18,
SYS TBL
CHIME
it will automatically convert this to 20 zones. Press
(
) button to proceed.
E
Note: The GEM-P3200 is limited to a combined maximum of 48 zones and
7 keypads. All 48 zones and 7 keypads may be programmed in the EZ
SYS TBL
CHIME
Program Mode. For more options, see Zone and Keypad Options in Direct
Address Programming.
SYS TBL
CHIME
Fire Zones (Appears for New Panel Only)
Enter the zone number of any Fire Zones (both 2-wire, 4-wire or wireless).
Valid entries are from 01 to 48. Directly enter each zone number, including
SYS TBL
CHIME
leading zeros, and press
zone(s). Press NEXT (
NOTE: If you are programming a 2 Area system, enter the zone number of
zones required for Areas 1 & 2. All fire zones are common to areas 1 and 2.
SYS TBL
CHIME
The Direct Address Program Mode can then be used to customize them as
needed. See Zone Options.
2-Wire Fire Zones (Appears for New Panel Only)
Enter the zone number of any Fire Zones (from previous question) which
are to be used with 2-wire smoke detectors. The only valid entries are 07
SYS TBL
CHIME
and 08. Directly enter each zone number, including leading zeros. Press
J
to save, and then repeat for any additional zone. NOTE: Only zones
which have been designated as Fire Zones can be programmed as 2 Wire
Fire zones. Press NEXT (
SYS TBL
CHIME
to "2-WF" position for 2-wire fire zones 7 and 8 (refer to Installation
Instructions).
Local System or C.S. Reporting System (Appears for New Panel Only)
Press YES (
for no zones to report (LOCAL SYSTEM).
SYS TBL
CHIME
SYS TBL
CHIME
followed by NO (
A,
. NOTE: Press the
0
J
to save, and then repeat for any additional
) button to proceed.
E
) button to proceed. NOTE: JP7 must be set
E
) button for all zones to report; press NO (
E
WI818D 08/00
) repeatedly until "17" is
F
button. Press
B
button for a zero. The system is
J
to save. Press NEXT
F
L
NAPCO Security Systems
1
) button