Table 2–7 Input Currents for 3-Phase Input Power
REQ'D INPUT
TERMINAL
JUMPER
CONNECTIONS
SW 5550AE
PFC* USA
F1 to F2
F1 to F2,
PFC INTL
F2 to F3
SW 3700AE
PFC USA
F1 to F2
F1 to F2,
PFC INTL
F2 to F3
SW 1850AE
PFC USA
None
PFC INTL
None
* Only Phase A and Phase B are present at the output
Operation Manual
MAXIMUM
MAXIMUM
LINE
NEUTRAL
CURRENT
CURRENT
27A RMS
Not Required
14A RMS
14A RMS
42A RMS
Not Required
42A RMS
72A RMS
27A RMS
Not Required
14A RMS
14A RMS
28A RMS
Not Required
28A RMS
48A RMS
15A RMS
Not Required
14A RMS
14A RMS
14A RMS
Not Required
14A RMS
25A RMS
CONNECT
1-PHASE
INPUT
POWER TO
F1, F3
F1, Neutral
F1, F3
F1, Neutral
F1, F3
F1, Neutral
Table 2–8 Single-Phase Input Configurations
F1-F3
FUSE
RATING
40A
20A
50A
50A
40A
20A
40A
40A
20A
20A
20A
20A
MAXIMUM
VOLTAGE
INPUT
CURRENT
187-264
30A RMS
VRMS, L-L
187-264
45A RMS
VRMS, L-N
187-264
30A RMS
VRMS L-L
187-264
30A RMS
VRMS L-N
187-264
15A RMS
VRMS L-L
187-264
15A RMS
VRMS L-N
Installation
RECOMMENDED
CIRCUIT BREAKER
RATING (MAX.)
40A RMS
20A RMS
50A RMS
50A RMS
40A RMS
20A RMS
40A RMS
40A RMS
20A RMS
20A RMS
20A RMS
20A RMS
RECOMMENDED
F1-F3
CIRCUIT
FUSE
BREAKER
RATING
RATING (MAX.)
40A
40A RMS
20A
40A RMS
40A
40A RMS
20A
40A RMS
20A
20A RMS
20A
20A RMS