Operation
3.3.4.2
EDIT Sub-Menu
The WAVEFORM menu allows you to EDIT a waveform in the scratchpad.
WAVEFORM
LOAD
EDIT
VIEW
SAVE
DELETE
EDIT Sub-Menu Status and Information Data:
Menu Item
Status and Information Line
FREQ
[waveform frequency]
Vrms
[output waveform voltage]
START
[starting phase angle]
TIME
[surge/sag duration]
STOP
[ending phase angle]
AMPL
[drop/spike voltage]
NOTES: Vrms is in terms of RMS voltage while AMPL is in terms of peak voltage.
Both of these values depend on the currently selected voltage range setting
in the INSTRUMENT menu.
Maximum frequency is determined by the selected waveform; see Section
3.4, Front Panel Programming Conventions for more information about
maximum frequency.
3-10
SW 5550AE • SW 3700AE • SW 1850AE
OUTPUT [OFF]
FREQ
Vrms
START
TIME
STOP
AMPL
Range
40–63 Hz or 40–500 Hz,
depending on waveform loaded
0–156 or 0–312 V
0–360°
0–1/Freq
Start–360°
-220.6 to 220.6 Vpeak (156 Vrms range)
-441.2 to 441.2 Vpeak (312 Vrms range)
Hz
V
Deg
ms
Deg
V