Elgar SW 5550AE Operation Manual page 57

Smartwave switching amplifier
Table of Contents

Advertisement

SW 5550AE • SW 3700AE • SW 1850AE
3.3.5.5
EXECUTE Sub-Menu
The SEQUENCE EXECUTE sub-menu allows the selection of the start, run, and stop
modes of a sequence. The front panel operation is defined here, but all modes are also
available via the GPIB. A sequence can be executed in any combination of the
following modes:
A sequence can be run in its entirety, or stepped through one segment at a time.
When in this "step" mode, the most recent segment can be repeated.
A sequence can be executed only once, or looped until the STOP command is
received.
A sequence can be terminated with the outputs automatically programmed to
0 volts, restored to the waveforms and values before the sequence began, or
remain at the waveforms and values of the last segment in the sequence. The
last two options will occur with no interruption in output power.
The SEQUENCE EXECUTE sub-menu selections are explained in Table 3–1.
SEQ MENU
LOAD
EDIT
SAVE
DELETE
EXECUTE
EXECUTE Sub-Menu Status and Information Data:
Menu Item
LOAD SEQ
SYNC
CONTROL
RUN MODE
STOP MODE
LOOP COUNT
Operation Manual
LOAD SEQ
SYNC
CONTROL
RUN MODE
STOP MODE ZERO
LOOP CNT
Status and Information Line
[<enter> to select sequence]
[sync output configuration]
[start/stop sequence]
[execute seg once or repeat]
[restore output on seg stop]
[loop execution count]
OUTPUT [OFF]
Name
SELECT SEG
STOP
LOOP
1
Range
Select Seg / Every Seg
Run / Step / Stop
Repeat / Single / Loop
Zero / Program / End Seg
1–9999
Operation
3-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw 3700aeSw 1850ae

Table of Contents