SW 5550AE • SW 3700AE • SW 1850AE
3.3.2
PROGRAM Menu
The PROGRAM menu allows you to:
Select a phase
•
Program amplitude–function polarity validates the amplitude input,
•
see Section 3.4 for more information
Program current limit, either value or level
•
Program frequency–maximum frequency is determined by the selected
•
waveforms for each phase, see Section 3.4, Front Panel Programming
Conventions, for more information about maximum frequency
Program phase offset (phase offset represents a phase lead)
•
Select a function to be output on the selected phase.
•
MAIN MENU
PROGRAM
MEASURE
WAVEFORM
SEQUENCE
INSTR
SYSTEM
PROGRAM Menu Status and Information Data:
Menu Item
Status and Information Line
PHASE A
[<enter> for next phase]
AMPL
[program output RMS/DC voltage] *
CURL
[program RMS/DC current limit]
FREQ
[program output frequency]
(default: 60 Hz)
θ ANG
[program phase angle offset]
FUNC
[program output waveform]
Operation Manual
OUTPUT [OFF]
PHASE A (or B or C)
AMPL
CURL
FREQ
θ
ANG
FUNC
Range/Default
Phases A, B, C
0–156 V or 0–312 V
(to 0.01V resolution)
0–16 A or 0–8 A (default: 5A)
*
40–63 Hz or 40–500 Hz
0–360° (default: 0°, 120°, 240°)
**
Default: Sine
Operation
V
A
Hz
Deg
3-5