Elgar SW 5550AE Operation Manual page 55

Smartwave switching amplifier
Table of Contents

Advertisement

SW 5550AE • SW 3700AE • SW 1850AE
The "CYCLES" Edit Field
When the field select cursor is at the CYCLES field, pressing F1 will toggle the SYNC
SELECT symbol "*". This is a flag used in conjunction with the SYNC field of the
Sequence Execute menu; if SYNC is set to SELECT SEG, only those segments that
are enabled will generate a sync signal at the front panel BNC connector. If SYNC is
set to EVERY SEG, every segment will generate a sync signal.
NOTE: The CYC field has a maximum input and display range of 9999. For FREQ
and TIME combinations that exceed 9999 cycles, the CYC field will still
indicate 9999. This limitation does not apply to GPIB control.
The "FREQ" Edit Field
The acceptable range of frequency is determined by the waveforms selected for Phases
A, B, and C.
The "AMPL" Edit Field
For information about the relationship between AMPL and FUNC, refer to Section 3.4,
Front Panel Programming Conventions.
3.3.5.3
SAVE Sub-Menu
The SEQUENCE menu allows you to assign a name to a new sequence and SAVE it
from the scratchpad to non-volatile memory.
1.
Use the Up/Down Arrow keys or the Knob to enter the custom waveform name.
Press the Right Arrow key to proceed to the next character; press the Left
Arrow key to backspace. The last character should be "–".
2.
Press the Enter key.
3.
Go to SAVE and press the Enter key again to save.
SEQ MENU
LOAD
EDIT
SAVE
DELETE
EXECUTE
Operation Manual
OUTPUT [OFF]
NAME
SAVE
Operation
3-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw 3700aeSw 1850ae

Table of Contents