Agency Requirements; Physical Specifications (All Models); Environmental Data - Elgar SW 5550AE Operation Manual

Smartwave switching amplifier
Table of Contents

Advertisement

General Description
1.7

Agency Requirements

The SmartWave is designed to meet the following agency requirements:
UL 3111
CUL 1010
EN 61010
EN 50081-2
EN 50082-1
IEC 1000-3-2, Annex A, Supply Source
IEC 725 Reference Impedance
IEC 801-2, -3 and -4
IEC 1000-4-13, Interharmonics Waveform Generator
FCC Part 15, Class A
1.8

Physical Specifications (All Models)

Height: 8.75" (222 mm)
Width: 19" (483 mm)
Depth: 23.5" (597 mm)
Weight: SW 5550AE: 126.5 lbs. (57.2 kg)
SW 3700AE: 100.5 lbs. (45.6 kg)
SW 1850AE: 73 lbs. (33.1 kg)
Cooling: Air is drawn in from the top and sides, and exhausted through the rear of the
chassis. 200 CFM is required for specified operation.
1.9

Environmental Data

Operating Temperature: 0°C to 45°C (32°F to 113°F).
Note temperature measured at air inlet of SW. If cabinet mounted, cabinet inlet air may
be rated at lower maximum temperature due to warming of inlet air.
Storage Temperature: -40°C to 70°C (-40°F to 158°F).
Humidity (Non-condensing): 0 to 80% at 31°C (88°F);
derate to 50% at 40°C (104°F).
Altitude: Operating: 10,000 ft. (3,048 m); non-operating: 40,000 ft. (12,192 m).