SW 5550AE • SW 3700AE • SW 1850AE
SYNC OUT selects the output sync signal to ON, OFF or EVENT. In the ON position,
the signal is driven by the output frequency of the waveform, or sequence settings. In
the EVENT position, a pulse will be generated for any change in VOLT, CURR, FREQ,
PHASE, or WAVEFORM.
The SYNC OUT setting only affects normal (non-sequence) mode. To set up the SW
so that a sync pulse only occurs for a specified sequence segment, set this parameter
to OFF. That way, before and after a sequence is run, no other sync pulses will occur.
Table 3–2 provides self-test result definitions.
BIT
MEANING
0001
LCD Test
0002
EPROM CKSUM
0004
NVRAM BANK 0 CKSUM
0008
NVRAM BANK 1 CKSUM
0010
RAM Test
0020
VXI Test
0040
QSCI Test
0080
GPIB Test
Operation Manual
Table 3–2 SELF-TEST Results Definitions
BIT
MEANING
0100
Battery Test
0200
QSPI Test
0400
DFI Test
0800
Speaker Test
1000
DWSB Self-Test 0
2000
DWSB Self-Test 1
4000
IWGB Self-Test 0
8000
IWGB Self-Test 1
Operation
3-23