Elgar SW 5550AE Operation Manual page 45

Smartwave switching amplifier
Table of Contents

Advertisement

SW 5550AE • SW 3700AE • SW 1850AE
3.3.2.2
Front Panel Store/Recall
The current state of the SW can be saved and restored using the Front Panel
Store/Recall feature. The following parameters are affected:
The current state of
the Program Menu:
Amplitude
Current Limit
Frequency
Phase Angle
Function
System User Menu:
Sync Out
The Store/Recall Menu can be accessed by pressing F2 from any Program menu edit
field. Setups are stored/recalled as a number from 0 to 49. The incr./dec. mode is not
available for this menu. Store/Recall functions do not affect the Lock/Unlock status of
the Program menu fields. If a field is locked, it will remain locked. However, the Recall
parameters for phases B and C will be updated.
To store a setup:
1.
Press F2 from any Program menu edit field.
2.
Move the field select cursor to "STORE SETUP."
3.
Enter a setup number from 0 to 49.
To recall a setup:
1.
Press F2 from any Program menu edit field.
2.
Move the field select cursor to "RECALL SETUP."
3.
Enter the previously stored setup number from 0 to 49.