Elgar SW 5550AE Operation Manual page 73

Smartwave switching amplifier
Table of Contents

Advertisement

SW 5550AE • SW 3700AE • SW 1850AE
15.
To retain the waveshape and display it on Phase A of the oscilloscope:
a.
Return to the MAIN MENU by pressing <Menu> twice.
b.
Select the PROGRAM Menu, then press <Enter>.
MAIN MENU
PROGRAM
MEASURE
WAVEFORM
SEQUENCE
INSTR
SYSTEM
16.
In the PHASE A sub-menu:
a.
Select FUNC with the Knob, then press <Enter> to place a box around the
waveshape selection.
b.
Rotate the Knob until SCRATCH is displayed, then press <Enter>. The
scratchpad waveform will now be displayed on Phase A of the oscilloscope.
17.
Press <Menu> or the Left Arrow key to return to the MAIN MENU.
Operation Manual
OUTPUT [OFF]
PHASE A
AMPL
120.00
CURL
FREQ
θ
ANG
FUNC
SCRATCH
V
5.00
A
60.00
Hz
0.00
Deg
Operation