Rate Limiting - Waters Network Systems MS1008-2G-4POE Operating Manual

Table of Contents

Advertisement

5.21

Rate Limiting

Rate limiting allows you to set up the bandwidth rate and packet limitation type per port.
Ingress Limit Packet Type – select the packet type to be filtered. The packet types
include all types of packets: broadcast/multicast/unknown unicast packets; broadcast/
multicast packets; broadcast packets only. The broadcast/multicast/unknown unicast
packets, broadcast/multicast packets and broadcast packets only used ingress
packets. The egress rate supports all types of packets.
All ports support port ingress and egress rate control. For example, if Port 1 is
10Mpbs, users can set its effective egress rate at 1Mbps and ingress rate is 500kbps.
The switch performs the ingress rate by packet counter to meet the specified rate.
Ingress – enter the port effective ingress rate. The default value is 0.
Egress – enter the port effective egress rate. The default value is 0.
Click Apply to confirm the settings.
Waters Network Systems
Figure 5.23 – Rate Limiting
MS1008-2G-4POE/PSX1008-2G-4PoE User's Manual
Page 45