SECTION 2: INSTALLATION
5.
Set the device address DIP switches 1 through 8 using the following table. Each device on the RS-485 network must have a
different address. You can configure up to 256 devices (address 0 .. 255) on the RS-485 network. When the switch is pushed
up (see the drawing above) it is ON.
Table 1. DIP address switch settings
Dome Address
1
0
OFF
1
ON
2
OFF
3
ON
4
OFF
5
ON
6
OFF
...
...
255
ON
6.
Set the network baud rate DIP switches 1 and 2 using the following table. Each device on the RS-485 network must use the
same baud rate. By default, the baud rate is set to 2400 baud (1 g OFF, 2 g OFF).
7.
Ensure that the camera lens and the inside of the lower dome is clean, then reinstall the lower dome. Position the dome onto
the back box, then tighten the two lock screws.
Do not put the protective foam back inside the dome. Save the foam and other packaging for possible use at a later time.
NOTE
10
SW1 (address) switch number
2
3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
...
...
ON
ON
Baud rate
2400
4800
9600
19200
4
5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
ON
ON
SW2 switches
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
6
7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
ON
ON
8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
ON

Advertisement