Epson Stylus Photo PX650/TX650/TX659/PX660/PX660 Premium/Artisan 635
4.2.4 Upper Housing/Scanner Cable Cover
C H E C K
The Scanner Unit cannot be opened enough to use a general
P O I N T
screwdriver for removing the screws that secure the Upper
Housing; therefore, this section describes removing the Scanner
Unit before removing the Upper Housing.
The screws that secure the Upper Housing can be removed with a
L-shaped screwdriver, a stubby driver or a similar tool without
removing the Scanner Unit, in that case, you can skip the step 3 to
5 (p.67).
L-shaped screwdriver
Figure 4-9. L-shaped Screwdriver and Stubby Driver
Parts/Components need to be removed in advance: None
Removal procedure
1.
Open the Scanner Unit.
2.
Release the hook of the Scanner Cable Cover and remove it in the direction of the
arrow.
Left inside
Scanner Unit
Scanner Cable Cover
Figure 4-10. Removing the Scanner Cable Cover
DISASSEMBLY AND ASSEMBLY
3.
Stubby driver
Middle Housing
Rib
Hook
Removal of Exterior Parts
Close the Scanner Unit and remove the screws (x2) of the hinge part.
Rear upper
1
Figure 4-11. Removing the Upper Housing (1)
Revision C
2
C.B.P. 3x10 (6±1 Kgfcm)
66
Confidential