Upper Housing / Printer Cover - Epson Stylus Photo R2000s Series Service Manual

Table of Contents

Advertisement

EPSON Stylus Photo R1900/R2880/R2000/R2000s/SC-P400 Series

4.2.7 Upper Housing / Printer Cover

1.
Remove the Decoration Plate Left/Right. (p.82)
2.
Remove the Panel Unit. (p.80)
3.
Open the Front Cover and CDR Tray Base.
Carriage and Opening/Closing the CDR Tray Base (p.75))
4.
Remove the seven C.B.P. M3 x 10 screws that secure the Upper Housing.
5.
Remove the Upper Housing while pulling out the CDR Sensor cable and the Panel
FFC through the cutout of the Upper Housing.
C.B.P. M3x10
C.B.P. M3x10
C.B.P. M3x10
Figure 4-18. Remove the Upper Housing
Disassembly And Assembly
(Refer to 4.1.6 Locking/Unlocking the
C.B.P. M3x10
Upper Housing
C.B.P. M3x10
Removing the Housings
Route the Panel FFC and CDR Sensor cable correctly as shown
in the following Figure.
Install the Upper Housing so that the Grounding Plate properly
protrudes through the cutout of the Upper Housing.
Upper Housing
Grounding Plate
Figure 4-19. Routing Panel FFC and CDR Sensor Cable
Tighten the screws in the order shown in
Revision I
Panel FFC
CDR Sensor cable
Figure
4-18.
83