80070208-0a02xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (PS 2 Therm
Fault)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702080a02xxxx or 0x800702080a02xxxx
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-supply fan.
2.
Use the IBM Power Configurator utility to ensure current system power consumption is under limitation. For
more information and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/
powerconfig.html.
3.
Replace power supply n. (n = power supply number)
8007020f-2201xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (TXT ACM
Module)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2201xxxx or 0x8007020f2201xxxx
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
If enabling TXT is not required, disable TXT from the Setup Utility.
1.
2.
If enabling TXT is required, verify that the TPM is enabled and activated from the Setup Utility.
3.
If the problem remains, contact your service representative.
80070208-0a02xxxx • 8007020f-2201xxxx