IBM System x3550 M4 Installation And Service Manual page 402

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

80010204-1d01xxxx • 80010204-1d02xxxx
4.
(Trained technician only) Replace the system board. (n = power supply number)
80010204-1d01xxxx
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (Fan
1A/1B Tach)
Explanation: This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d01xxxx or 0x800102041d01xxxx
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d02xxxx
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (Fan
2A/2B Tach)
Explanation: This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d02xxxx or 0x800102041d02xxxx
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
384
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents