IBM System x3550 M4 Installation And Service Manual page 494

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

806f040c-2004xxxx • 806f040c-2005xxxx
806f040c-2004xxxx
[PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 4)
Explanation: This message is for the use case when an implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2004xxxx or 0x806f040c2004xxxx
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit
reached), follow the suggested actions for that error event and restart the server.
3.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory
event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the
DIMM through the Setup utility or the Advanced Settings Utility (ASU).
806f040c-2005xxxx
[PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 5)
Explanation: This message is for the use case when an implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2005xxxx or 0x806f040c2005xxxx
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
Make sure the DIMM is installed correctly.
1.
2.
If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit
reached), follow the suggested actions for that error event and restart the server.
3.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory
event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the