IBM System x3550 M4 Installation And Service Manual page 528

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

806f060d-0403xxxx • 806f060d-0404xxxx
806f060d-0403xxxx
Array [ComputerSystemElementName] has failed. (Drive 3)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0403xxxx or 0x806f060d0403xxxx
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
Replace the RAID adapter.
4.
Replace the hard disk drive that is indicated by a lit status LED.
5.
806f060d-0404xxxx
Array [ComputerSystemElementName] has failed. (Drive 4)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0404xxxx or 0x806f060d0404xxxx
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
Replace the RAID adapter.
4.
Replace the hard disk drive that is indicated by a lit status LED.
5.
510
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links: