IBM System x3550 M4 Installation And Service Manual page 712

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

218-806-000 • 218-901-000
218-806-000
Brocade:InternalLoopbackTest Aborted
Explanation: The test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
218-900-000
Brocade:MemoryTest Failed
Explanation: A failure was detected while testing the adapter memory.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
218-901-000
Brocade:ExternalLoopbackTest Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.
694
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading