806f0a0c-2002xxxx • 806f0a0c-2003xxxx
806f0a0c-2002xxxx
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 2)
Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c2002xxxx or 0x806f0a0c2002xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in
place and correctly installed, and that the server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the specifications.
3.
If a fan has failed, complete the action for a fan failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2003xxxx
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 3)
Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c2003xxxx or 0x806f0a0c2003xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in
place and correctly installed, and that the server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the specifications.
3.
If a fan has failed, complete the action for a fan failure.
4.
Replace DIMM n. (n = DIMM number)
536
IBM System x3550 M4 Type 7914: Installation and Service Guide