IBM System x3550 M4 Installation And Service Manual page 706

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

405-805-000 • 405-900-000
405-805-000
BRCM:TestLoopbackMAC Test Aborted
Explanation: Loopback testing at the MAC layer was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-806-000
BRCM:TestLoopbackPhysical Test Aborted
Explanation: Loopback testing at the physical layer was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-807-000
BRCM:TestLEDs Test Aborted
Explanation: Verification of status LEDs was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-900-000
BRCM:TestControlRegisters Test Failed
Explanation: A failure was detected while testing internal MAC registers
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
688
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents