IBM System x3550 M4 Installation And Service Manual page 162

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

DC power-supply LEDs
IN OK
OUT OK
On
On
Off
Off
Off
Off
Off
On
Off
On
On
Off
On
Off
On
On
144
IBM System x3550 M4 Type 7914: Installation and Service Guide
Error (!)
Description
Off
Normal operation.
Off
No dc power to the
server or a problem
with the dc power
source.
On
The power supply
has failed.
Off
The power supply
has failed.
On
The power supply
has failed.
Off
Power-supply not
fully seated, faulty
system board, or
the power supply
has failed.
On
The power supply
has failed.
On
The power supply
has failed.
Action
1. Check the dc power to the
server.
2. Make sure that the power
cord is connected to a
functioning power source.
3. Restart the server. If the error
remains, check the
power-supply LEDs.
4. If the problem remains,
replace the power-supply.
Replace the power supply.
Replace the power supply.
Replace the power supply.
1. Reseat the power supply.
2. Follow actions in the "Power
problems" on page 166.
3. If the OVER SPEC LED on
the light path diagnostics is
lit, follow the actions in
"Light path diagnostics
LEDs" on page 137.
4. If the OVER SPEC LED on
the light path diagnostics is
not lit, check the error LEDs
on the system board and the
IMM2 error messages. Follow
steps in "Power problems"
on page 166 and "Solving
power problems" on page
175 until the problem is
solved.
Replace the power supply.
Replace the power supply.
Notes
This is a normal
condition when no dc
power is present.
Typically indicates a
power-supply is not
fully seated.