IBM System x3550 M4 Installation And Service Manual page 545

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

806f090c-2003xxxx
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 3)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2003xxxx or 0x806f090c2003xxxx
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2004xxxx
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 4)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2004xxxx or 0x806f090c2004xxxx
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2005xxxx
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 5)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2005xxxx or 0x806f090c2005xxxx
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
Reseat the DIMM, and then restart the server.
1.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2003xxxx • 806f090c-2005xxxx
Appendix A. Integrated management module II (IMM2) error messages
527

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents