Configuring Industrial Defender Addresses
Figure 228: Industrial Defender Configuration – IP addresses saved
The Appliance Address is the IP address of the SEM unit. The IP address of the
RuggedRouter must also be specified as Source Address. Once this is done, save
these addresses by clicking on the Save Changes button.
Retrieving an Industrial Defender Key
Once the addresses are saved, a key can be retrieved from the SEM unit. To do so,
enter the correct password, as specified on the SEM unit, and then click Obtain a
new key. In case of error, e.g. a password mismatch, an error message to that effect
will be shown at the top of the page.
Figure 229: Industrial Defender Configuration - key obtained