C7 Commands - Dalsa P-2 Series User Manual

Pirahna 2 series line scan ccd cameras
Table of Contents

Advertisement

73
GCP Screen
Exposure Time:
End-Of-Line Sequence:
Upper Threshold:
Lower Threshold:
Region of Interest:

C7 Commands

The following table lists all of the commands available to the camera user. The first
column of the table lists command codes returned as first code from
Code
Parameters:
0
i = integer
f = float
t = tap selector
s = string
x1 = pixel start
number
x2= pixel end number
[]= optional
parameter
1
03-32-00493-11
Command
calibrate_analog_gain
calibrate_analog_offset
Desctiption
section 3.9 Setting Line Rate
and Exposure Mode for details.
Current exposure time setting.
197.950 uSec
Value is set with the set
command. See section 3.9
Setting Line Rate and Exposure
Mode for details.
States whether an end of line
on
sequence is turned on or off.
Set using the eol command.
See section 3.17 Generating Test
Patterns for details.
Upper threshold value set with
240
the sut command.
Lower threshold value set with
15
the slt command.
Region of interest size set with
0001-4096
the roi command. See section
3.10 Setting a Region of Interest
for details.
Short
Parameters
Form
cag
t i
cao
t i
Piranha2 User's Manual
.
gps
Description
Calibrates the analog gain. The
first parameter is the tap
selection 1 to 4, 0 for all taps.
The second parameter is a line
average in a range from 64 to
251DN for 8-bit mode and 256
to 1007DN for 10-bit. This
command requires a constant
light input and only works in
uncalibrated mode.
Calibrates the analog offset.
The first parameter is the tap
selection 1 to 4, 0 for all taps.
The second parameter is a line
average in a range from 1 to
100DN for 8-bit mode and 4 to
DALSA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents