Optical, Mechanical, and
Thermal Considerations

4.1 Mechanical Interface

The camera's electronics are housed in a ruggedized lightweight aluminum case. See
Error! Reference source not found. and Error! Reference source not found..
Mounting
The camera can be mounted using the M3 holes (metric-threaded) on its base or top, and
on its front plate at the corners.
Environment
The camera and cables should be shielded from environmental noise sources for best
operation. The camera should also be kept as cool as possible. The specified operating
temperature is 10–50°C measured at the front plate, (the corresponding ambient
temperature range with still air is 0°C to 37°C). Mounting holes (refer above) allow you to
attach heat sinking.
Thermal Management
For any CCD camera optimal performance is achieved by transferring heat away from the
sensor. Keeping a sensor "cool" reduces the amount of dark current generated. Dark
current is the leading contributor to FPN, PRNU, dark offset, random noise and other
performance specifications, especially when a camera is significantly gained (i.e. +10db).
Generally, dark current doubles for every 7°C increase in temperature at the sensor and
increases linearly with integration time. Further variations in dark current cannot be
compensated for with our flat-field correction algorithms. For this reason, at high gains
(+10dB), high temperatures (40°C front plate), and low line rates, it is recommended that
you recalibrate the flat-field coefficients when the temperature shifts by ±10°C.
Note: Upon initial power-up the front plate camera temperature is near ambient. It is
recommended to perform flat-field correction once the camera gets within 10°C of its