Rebooting The Camera; Setting The Pre-Trigger - Dalsa P-2 Series User Manual

Pirahna 2 series line scan ccd cameras
Table of Contents

Advertisement

41
Note: by default all monitoring tasks are enabled except voltage monitoring.
Example: enable all monitoring tasks
wed 0 1
Example: disable EXSYNC presence
wed 3 0
Temperature Measurement
The temperature of the camera can be determined by using the
command will return the temperature inside the cover in degrees Celsius. For proper
operation, this value should not exceed 75°C.
Voltage Measurement
The command
up. If they are within the proper range, the camera returns OK>. Otherwise the camera
returns an error message. Note that the voltage measurement feature of the camera
provides only approximate results (typically within 10%). They should not be used to set
the applied voltage to the camera. The purpose of this test is to isolate gross problems
with the supply voltages.

3.19 Rebooting the Camera

The command
Previously saved pixel coefficients are also restored.

3.20 Setting the Pre-trigger

A pre-trigger may be required for some frame grabbers.
To set the pre-trigger, use the command:
Syntax:
Syntax Elements:
Example:
03-32-00493-11
checks the camera's input voltage and internal voltages during power-
vv
reboots the camera. The camera starts up with the last saved settings.
rc
sp i
i
Pretrigger value from 0 to 15.
sp 10
Piranha2 User's Manual
command. This
vt
DALSA

Hide quick links:

Advertisement

Table of Contents
loading