Returning Camera Settings with Get Commands

You can also retu rn ind ivid u al cam era settings by inserting a ―
com m and that you w ant to qu ery. If the com m and has a tap or pixel nu m ber param eter,
you m u st also insert the tap nu m ber or pixel nu m ber that you w ant to qu ery. Refer to
Table 14 below for a list of available com m and s. To view a help screen listing the
follow ing get com m and s, u se the com m and
Table 14: Get Commands
Syntax
get cao
get ccf
get ccp
get clm
get css
get els
get epc
get gcm
get gcs
get gcv
get gfc
get gl
get gla
get gsf
get lpc
03-032-10216-06
All manuals and user guides at all-guides.com
Parameters
Description
t
Returns the analog offset for the tap ind icated
t = tap selection, either 1 to 8, or 0 for all taps
x1 x2
Returns the FPN pixel coefficients for the pixel range
ind icated .
x1 = Pixel start number
x2= Pixel end number
x1 x2
Returns the PRNU pixel coefficients for the pixel range
ind icated .
x1 = Pixel start number
x2= Pixel end number
Returns the current Camera Link mod e.
Returns the number of line samples averaged for pixel
coefficient calculations or for output of
Returns w hether the end -of-line statistics are turned off or
on.
0: Off
1: On
Returns w hether pixel coefficients are enabled or
d isabled .
The first parameter returns the FPN coefficients setting
w here:
0 = FPN coefficients d isabled
1 = FPN coefficients enabled
The second parameter returns the PRNU coefficients
setting w here:
0 = PRNU coefficients d isabled
1 = PRNU coefficients enabled
Returns the camera's mod el number
Returns the camera's serial number
Returns the camera's softw are version.
x
Returns the FPN pixel coefficient for the pixel ind icated .
x1 x2
Returns pixel values for the pixel range specified .
x1 x2
Returns the average of the pixel range ind icated .
i
Returns the frequency of the Camera Link control signal
ind icated , either 1, 2, 3, or 4.
Returns the current coefficient set number.
get"