2.4 Power Supplies

The camera requires a single voltage input (+12V to +15V). The camera meets all
performance specifications using standard switching power supplies, although well-
regulated linear supplies provide optimum performance. See the Performance
Specifications for current requirements.
When setting up the camera's power supplies follow these guidelines:
See section 1.3 for power requirements.
WARNING: It is extremely important that you apply the appropriate voltages to your camera.
!
Incorrect voltages will damage the camera. Protect the camera with a fast-blow fuse between
power supply and camera.
Visit http://vfm.dalsa.com for a list of companies that make power supplies that meet
the camera's requirements. The companies listed should not be considered the only
choices. Many high quality supplies are available from other vendors. DALSA assumes
no responsibility for the use of these supplies.

2.5 Control Inputs, Camera Link

The camera accepts control inputs through the Camera Link MDR26F connector.
are optional. The camera ships in exposure mode 1 (maximum line rate and exposure time). All
Camera Control (CCx) signals are in a logic HIGH state.
the serial interface. Power-on rate is always 9600 baud. Data rate for the 40MHz model is
always 40MHz. Data rate for the 30MHz model is always 30MHz.
The external control signals, EXSYNC and PRIN, are optional and enabled through the
serial interface.
PRIN
PRIN is an optional input signal used for exposure control (PRIN).
PRIN
High
03-32-00493-11
Hirose 6-pin Circular Male
1
6
5
2
3
4
Mat ing Par t: HIRO SE
HR10A -7P-6S
Description
Pin
+12V to +15V
4
+12V to +15V
5
+12V to +15V
6
Protect the camera with a fast-blow fuse between power supply and camera.
Do not use the shield on a multi-conductor cable for ground.
Keep leads as short as possible to reduce voltage drop.
Description
GND
GND
GND