DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance.
▪ Do not touch any electrical switch; do
not use any phone in your building.
▪ Leave the building immediately.
▪ Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
4003901-05
©2014, Miles Industries Ltd.
L
EGEND
DV Gas Insert
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the
ENGINE ONLY. A front is also REQUIRED to
complete this installation. A barrier screen is pro-
vided with the front. Refer to the manual sup-
plied with the front for installation.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading

Summary of Contents for Valor LEGEND 739JLN

  • Page 1 EGEND DV Gas Insert 739JLN/P (Logs) & 739IRN/P (Rocks) Installation & Owner’s Manual DANGER I N S TA L L E R L e a v e t h i s m a n u a l HOT GLASS WILL w i t h t h e a p p l i a n c e .
  • Page 2: Table Of Contents

    Table of Content FOR THE OWNER FOR THE QUALIFIED INSTALLER Safety Precautions ..........3 Specifi cations ............15 Safety and Your Fireplace ........4 Overview..............16 Owner’s Information ..........5 Dimensions ............17 Operating Your Fireplace for the First Time ....5 Cavity ..............
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully Due to the high temperature, the appliance should be before starting the installation. FAILURE TO FOLLOW LOCATED out of traffi c areas and away from furniture these installation instructions may result in possible fi re and draperies.
  • Page 4: Safety And Your Fireplace

    Safety and Your Fireplace Safety and Your Fireplace Please Read and Carefully Follow all Safety Warnings and Operating Instructions Contained in Your Owner’s Manual (Replacement Manuals are available by contacting our service department at 1-800-468-2567 or visit www.valorfi replaces.com). withdraw in the event of accidental Please Follow These Important contact with a hot surface.
  • Page 5: Owner's Information

    OWNER’S Owner’s Information INFORMATION Thank You ... WARNING For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages is fully tested during the production process for your 3 and 4 of this manual BEFORE operating safety and comfort.
  • Page 6: Cleaning Your Fireplace

    OWNER’S Owner’s Information INFORMATION Cleaning Your Fireplace To remove the window for cleaning: 1. Unhook the front with barrier screen. WARNING WARNING 2. On the window, DO NOT TOUCH THE GLASS WHILE IT IS HOT! turn each bolt a Let the fi replace cool fi rst before cleaning it. quarter turn to disengage the Important - Glass cleaning - Mineral deposits...
  • Page 7: Checking Pilot And Burner Fl Ames

    OWNER’S Owner’s Information INFORMATION 6. If the Hot Glass Warning plate has been removed Rock fuel bed from the front lower corner of the window, A black discoloration may form over time at the front reinstall it by sliding it between the glass and bottom of the 6-rock original fuel bed;...
  • Page 8: Using Handset Wall Holder

    OWNER’S Owner’s Information INFORMATION Using Handset Wall Holder How to Turn Your Fireplace OFF (including pilot) Your fi replace equipment includes a wall holder Familiarize yourself with each of these methods before to store the handset. If it hasn’t be installed, refer operating your fi...
  • Page 9: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 10 OWNER’S Remote Control Operation INFORMATION MODES OF OPERATION • Press and hold (small fl ame) button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 11 OWNER’S Remote Control Operation INFORMATION SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” TEMPERA- SETTING THE “DAYTIME” TEMPERATURE TURE Default Settings: (sun), 23ºC / 74ºF Default Settings: (moon), “ ” (OFF) TEMP T E M P • Briefl y press SET button to scroll to •...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING PROGRAM TIMERS SETTING P1 OFF TIME • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 13: Options

    OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ 6:00 a.m.— ☼ ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 14: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
  • Page 15: Specifi Cations

    Manifold Pressure (in w.c.) 10.0 Minimum Supply Pressure 11.0 The 739 Legend G3 is supplied as natural gas or (in w.c.) propane gas and is fi eld convertible between fuels. See instructions packaged with the conversion kit for further Maximum Supply Pressure 10.0...
  • Page 16: Overview

    QUALIFIED Overview INSTALLER This appliance may ONLY be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. DO NOT install into combustible construction. This appliance is NOT APPROVED for installation with a zero clearance kit. WARNING WARNING Chimney Terminal Cap...
  • Page 17: Dimensions

    QUALIFIED Dimensions INSTALLER 28-5/8” (727 mm) 19-1/2” (495 mm) 12” (305 mm) or 12-5/8” (321 mm) Varies with outer trim options Optional Outer Trim or Surround sold separately 9-3/8” (238 mm) or 10” (254 mm) Varies with outer trim options 20”...
  • Page 18: Clearances

    QUALIFIED Clearances INSTALLER WARNING WARNING Some materials or items, although safe, may discolor, shrink, warp, crack, peel, and so on because of the heat produced by the fi replace. Avoid placing candles, paintings, photos, and other items sensitive to heat around the fi replace. Combustible Mantel Clearances Mantel Pro- 1”...
  • Page 19: Venting

    QUALIFIED Venting INSTALLER Typical Vent Installation See the Approved Venting Components list on page 34 of this manual. Vent Location The vent terminal must be located through the roof. This direct Terminal Cap vent appliance is designed to operate when an undisturbed airfl...
  • Page 20: Existing Fireplace Preparation

    QUALIFIED Installation Planning INSTALLER Only qualifi ed licensed or trained personnel should install this appliance. Installer—READ THIS FIRST 12. Put batteries in receiver and remote control 1. YOU NEED TO KNOW FROM THE handset. HOMEOWNER what accessories (surround, door, etc.) will be installed with this fi replace; 13.
  • Page 21: Unpack The Appliance

    QUALIFIED Existing Fireplace Preparation INSTALLER Gas Line Routing Combustible Mantels Plan the routing of the gas line before proceeding. Combustible mantel clearances must conform to those Utilize the existing hole for the gas line. If the factory- required for the original solid-fuel fi replace into which built fi...
  • Page 22: Remove Window

    QUALIFIED Installation INSTALLER Remove Window The window is held in place by four spring-loaded bolts, two at the top and two at the bottom. 1. To remove the window, turn each bolt a quarter turn to disengage the bolt pin. 2.
  • Page 23: Connect Venting

    QUALIFIED Installation INSTALLER Connect Venting IMPORTANT: This appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process.
  • Page 24: Connect Gas Supply

    QUALIFIED Installation INSTALLER Connect Gas Supply Pressure Test Points The gas supply inlet connection is a 3/8” NPT female The minimum supply pressure is given in the section connector and is located on the left hand side of the Specifi cations of this manual—page 15. control valve.
  • Page 25: Install Liner Panels

    QUALIFIED Installation INSTALLER Install Liner Panels 4. Rotate the anchor up and out of the way and slide the right hand side panel against the fi rebox side. The following guidelines apply for all liners. The panel should be parallel to the edge of the 1.
  • Page 26: Install Ceramic Logs (739Jl)

    QUALIFIED Installation INSTALLER Install Ceramic Logs (739JL) Unpack the ceramic logs very carefully to avoid damaging the fragile material. Install the logs as shown below. Please note that the position of the logs is critical to ensure proper performance of the appliance. 1.
  • Page 27 QUALIFIED Installation INSTALLER 4. Place the front right log on the burner and slide it to 6. Place the lower end of the center right log onto the the left against the front left log. pin on the front right log. Rest the narrow end in the notch into the rear log.
  • Page 28: Install Ceramic Rocks (739Ir)

    QUALIFIED Installation INSTALLER Install Ceramic Rocks (739IR) Unpack the ceramic rocks kit very carefully to avoid damaging the fragile material. Install the components as shown below. Please note that the position of the rocks and twigs (if used) is critical to ensure proper performance of the appliance.
  • Page 29 QUALIFIED Installation INSTALLER 4. The underside of each ceramic rock is identifi ed by a number and a specifi c protruding positioning triangle. Rock Install the six rocks from left to right starting identifi cation with rock no. 1. Triangular hole in ceramic base...
  • Page 30: Refi T And Check Window

    QUALIFIED Installation INSTALLER Refi t and Check Window 1. To refi t the window, place the window against the fi rebox’s opening frame. Make sure that the wider part of the window frame is at the bottom. 2. While you hold it, push in and turn the two bottom spring-loaded bolts a quarter turn to engage their pin.
  • Page 31: Check Operation

    QUALIFIED Installation INSTALLER Check Operation In a few unusual installations, the fl ame picture may be improved by adjusting the aeration. The need for Turn the fi replace fl ame up and down using the adjustment should be determined only by operating the remote control to confi...
  • Page 32: Install Handset Wall Holder

    QUALIFIED Installation INSTALLER Install Handset Wall Holder Alternative 2 Alternative 3 Packing Contents: The remote control kit for this fi replace comes complete with a wall-mounted holder. 1 Wall Bracket A This holder is not required in all installations 2 Screws B 1 Screw C but is provided as an optional feature for 2 Wall Anchor D...
  • Page 33: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Optional Wall Switch Kit 1265WSK Connector Yellow GV60 Wiring Diagram...
  • Page 34: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 700, 739 , 780, 785 and RF24DV Venting Parts Code / availability by Manufacturer Venting Parts Description 4DVC 940264 HSDV4658- Standard Co-axial 46DVA-VC 4DT-VC TM-4VT — 4DH-1313 — 940364 1313 940206LP...
  • Page 35: Warranty

    OWNER’S Warranty INFORMATION If you have a problem with this unit, please contact your dealer or supplier immediately. Under no circumstances should you attempt to service the unit in any way by yourself. The warranties in paragraphs 1 and 2 are provided only to the fi...
  • Page 36: Spare Parts

    OWNER’S Spare Parts INFORMATION Part Part Code Description Code Description Number Number Exhaust Slide Assembly 4001133 Module Gasket—Front 4000173 Exhaust Slide Gasket 4001662 Module Gasket—Left 4000181 Fan Closure Plate 4001136 Olive Nut for Pilot Pipe 220K913 Port Cover 4001820 Pipe—Valve to Pilot 4001838 Rock Support (739IR) 4001768...
  • Page 37 OWNER’S Spare Parts INFORMATION Part Code Description Number Right Fluted Panel (739IR) 4001813 Right Brick Panel (739JL) 4001810 Glass Panel (739IR) 4001836 Front Support—Platform (739IR) 4001835AH Ceramic Platform (739IR) 4001832 Log Set Complete (739JL) 4003794 Rear Log (739JL) 4003787 LH Top Log (739JL) 4003788 RH Top Log (739JL) 4003789...
  • Page 38 OWNER’S Spare Parts INFORMATION 12 13 45a, 45b...
  • Page 39 Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 40 Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...