Valor 700MN Homeowner's Manual

Insert gas fireplaces
Hide thumbs Also See for 700MN:

Advertisement

Quick Links

Homeowner's Manual
G3.5
G3.5
with
Canadian Patent 2,717,779 Issued October 24 2017
US Patent 10,060,624 Issued August 28 2018
US Patent 10,935,246 Issued March 2 2021
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings
exactly could result in serious
injury, death, or property damage.
Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
DANGER
4008153-07
Insert Gas Fireplaces
natural gas 700MN / 700XN
propane gas 700MP / 700XP
Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
Hot glass
will cause burns.
Do not touch glass
until cooled.
Never allow children
to touch glass.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fi re department.
A barrier designed to reduce
the risk of burns from the hot
viewing glass is provided with this
appliance and must be installed for
the protection of children and
other at-risk individuals.

Advertisement

Table of Contents
loading

Summary of Contents for Valor 700MN

  • Page 1 Homeowner’s Manual G3.5 G3.5 Insert Gas Fireplaces natural gas 700MN / 700XN propane gas 700MP / 700XP with Canadian Patent 2,717,779 Issued October 24 2017 US Patent 10,060,624 Issued August 28 2018 US Patent 10,935,246 Issued March 2 2021 Do not touch any electrical switch; do ▪...
  • Page 2 Ltd. reserves the right to change or modify any information or specifi cations without notice. Miles Industries Ltd. grants no warranty, implied or stated, for the installation or maintenance of your heater, Valor Fireplaces and assumes no responsibility for any consequential 190–2255 Dollarton Highway damage(s).
  • Page 3: Table Of Contents

    fi replace, do not try to repair the unit yourself. Contents Your Valor Fireplace Safety and your fi replace .......... 4 Here are some important details about your Valor Child safety and your fi replace ......... 6 fi replace, should you need to contact your dealer. Model: _________________________________________ Getting started ............
  • Page 4: Safety And Your Fireplace

    Read and understand all instructions carefully before operating your fi replace. Failure to follow these instructions may result in possible fi re hazard and will void the warranty. Replacement manuals are available by contacting Valor Customer Service at 1-800-468-2567, or by visiting valorfi...
  • Page 5 Safety and your fireplace Glass window Intended use • This appliance is designed and approved as a supple-  WARNING mental heater and provides the potential for most energy conservation when used while attended. The Do not operate this appliance with the use of an alternate primary heat source is advisable.
  • Page 6: Child Safety And Your Fireplace

    Read and carefully follow all safety warnings and operating instructions contained in this manual, and follow these important child safety precautions and recommendations: • Parts of your Valor Fireplace become extremely A physical barrier is recommended if there are hot while in operation. The glass window tempera- at-risk individuals in the house.
  • Page 7: Getting Started

    Valor safety gas shut-off There is important information on both sides of the For your safety, Valor fi replaces are fi tted with a card. It must be left with the fi replace when you are fl ame supervision device which will shut-off the gas done.
  • Page 8: Parts Of Your Fireplace

    Parts of your fireplace Here are the major components of your installed fireplace, with the protective barrier installed. Your individual fireplace may appear differently depending on your model and installed options. Barrier Screen (mesh) Window Frame Trim Liners Side Doors Fireplace info card behind the right door Fuel Bed Logs, embers, pebbles...
  • Page 9: Operating Your Fireplace

    fi replace - see page 7 to learn how to access it. Control such as temperature or program Also, a copy of this card is reproduced in Appendix A settings, see Appendix A-Remote Control of the Installation Manual. Operation on page 23 of this manual or visit valorfi replaces.com/remotes...
  • Page 10: Preventing Inadvertent Ignition

    Automatic shut-off (in certain conditions) Your fi replace’s remote control is equipped with an automatic shut-off mechanism which is activated in certain conditions. See Remote Control Operation at Appendix A or valorfi replaces.com/remotes for a description of this feature.
  • Page 11: Replacing Batteries

    Replacing batteries 4. Disconnect it from its cable. Do not pull on the wire!.  WARNING Do not attempt to access the batteries while the fi replace is hot! Let the fi replace cool fi rst before touching it!  Caution Do not use a screwdriver or other metallic object to remove the batteries from the 700M Battery holder 700X Battery holder...
  • Page 12: Annual Service And Maintenance

    Annual service and maintenance We recommend having your fi replace serviced before initial use, and at least once per year by a qualifi ed service technician. Contact your dealer quoting the model serial number, if possible. It will be helpful if the fi replace’s serial number can also be quoted.
  • Page 13: Cleaning Your Fireplace

    Cleaning your fireplace 3. Locate the window retainer hooks.  WARNING Risk of severe burns! Surfaces of the fi replace are very hot during operation. Ensure fi replace has cooled off before touching it. Remove the window for cleaning 4. Pull the levers toward you and unhook them from 1.
  • Page 14 Follow all instructions on the bottle/container. Log position is important in your Valor fi replace because it can optimize the beauty of the fl ame and • Our dealers have experienced good results from the the combustion effi...
  • Page 15 Damage caused by incorrect window 4. Apply fi rm hand pressure around the window installation is not covered by the Valor frame to ensure the window is sealed tight against Warranty. the fi rebox.
  • Page 16 Cleaning your fireplace 5. If the Hot Glass Warning plate has been removed from the front lower corner of the window, reinstall it by sliding it between the glass and the frame as indicated below. Hot Glass Plate 6. Reinstall side panels. Reinstall the trim with barrier screen.
  • Page 17: Checking Pilot And Burner Flames

    Checking pilot and burner flames Typical fl ame appearance - 700M The pilot light and burner fl ames should be checked periodically. Check after the fi re has been on for at Traditional Logs least 30 minutes. The pilot fl ame must cover the tip of the thermocouple probe.
  • Page 18 Checking pilot and burner flames Typical fl ame appearance - 700X Driftwood Logs Pilot Light Location  Note Murano Glass The height and color of your flames can vary depending on fuel type, fuel quality and mixture, altitude, and aeration adjustment at or after installation.
  • Page 19: Frequently Asked Questions

    If the fi replace still won't turn on after that, call your dealer for further information. Your fi replace may require service by a qualifi ed service technician. Visit valorfi replaces.com/contact for a list of dealers near you. I've just started my fi replace When operating your fi...
  • Page 20 Where can I purchase parts Any of our Valor dealers are able to order parts or provide fi eld service. for my fi replace? Please contact your dealer - see page 3 - or visit valorfi...
  • Page 21: Valor ® Warranty

    Installation and maintenance must be performed by 5. No Other Warranty an authorized and trained dealer in accordance with All obligations to repair this unit are de ned in this warranty.
  • Page 22: Valor ® Outdoor Installation Warranty

    The Company does not allow anyone to extend, b) Installation and maintenance must be performed alter or modify this warranty and assumes no...
  • Page 23: Appendix A-Remote Control Operation

    Appendix A-Remote Control Operation Radio Frequency Turn Fireplace ON 315 MHz for USA and Canada. Press buttons until you hear a short beep; release buttons. This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Beeps continue until pilot is lit.
  • Page 24 Appendix A-Remote Control Operation Setting ºC/24-hr or ºF/12-hr Manual Mode M A N clock Manual ame height adjustment. In MAN mode, press buttons Daytime Temperature Mode until temperature / clock display TEMP changes from When pilot is lit, room temperature °F / 12-hour °C / 24-hour is measured and compared to set...
  • Page 25 Appendix A-Remote Control Operation Circulating Fan Operation Setting Program Timers (if equipped) You can program two periods of time between 12 am Circulating fan has 4 speed levels from and 11:50 pm in each 24-hour cycle. low to high (1 to 4 bars). Programs P1 and P2 must be set in the following order Press SET to scroll to .
  • Page 26 Appendix A-Remote Control Operation Setting P2 high and low temperature times. Repeat same steps as Setting P1. When all settings are complete, press to save them. Timer Programming Example (default temperatures shown) 6:00 am 8:00 am 4:00 pm 10:00 pm 6:00 am high temp low temp...

This manual is also suitable for:

G3.5700xn700mp700xp

Table of Contents