Safety Timers; Water Assist Harvest Feature - Manitowoc QuietQube Indigo Series Technician's Handbook

Ice machines
Hide thumbs Also See for QuietQube Indigo Series:
Table of Contents

Advertisement

SAFETY TIMERS

The control board has the following non-adjustable
safety timers:
The ice machine is locked into the freeze cycle for
6 minutes before a harvest cycle can be initiated.
This can be overridden by initiating a manual
harvest. Refer to "Manual Harvest" on page 90
The maximum freeze time is 60 minutes at which
time the control board automatically initiates a
harvest sequence (steps 5 & 6).
The maximum harvest time is 3.5 minutes at which
time the control board automatically ends the
harvest cycle. When the bin switch is closed a
freeze sequence initiates (steps 3 & 4). When the
bin switch is open an automatic shutoff sequence
initiates.
The maximum water fill is 12.5 minutes (16.5
minutes for dual evaporator models).

WATER ASSIST HARVEST FEATURE

Twin Evaporators Only:
Typical duration of a Harvest sequence is less than 2.5
minutes. When the Harvest sequence time reaches 4
minutes, the following occurs:
4 minutes into a Harvest sequence: The water fill valve
will energize to fill the trough with water.
5 minutes into a Harvest sequence: The water pump
will energize and flow water over the evaporators.
The water fill valve and water pump remain on until all
bin switches have been activated, or until the 7-minute
Harvest sequence time limit is reached.
110
Part Number STH026 8/12

Advertisement

Table of Contents
loading