SAFETY TIMERS

The control board has the following non-adjustable
safety timers:
The ice machine is locked into the freeze cycle for 6
minutes before a harvest cycle can be initiated. This
can be overridden by initiating a manual harvest.
Refer to "Manual Harvest" on page 89
The maximum freeze time is 60 minutes at which
time the control board automatically initiates a
harvest sequence (steps 5 & 6).
The maximum harvest time is 3.5 minutes at which
time the control board automatically ends the
harvest cycle. When the bin switch is closed a freeze
sequence initiates (steps 3 & 4). When the bin switch
is open an automatic shutoff sequence initiates.
The maximum water fill is 12.5 minutes (16.5 minutes
for dual evaporator models).

WATER ASSIST HARVEST FEATURE

Twin Evaporators Only:
Typical duration of a Harvest sequence is less than 2.5
minutes. When the Harvest sequence time reaches 4
minutes, the following occurs:
4 minutes into a Harvest sequence: The water fill valve
will energize to fill the trough with water.
5 minutes into a Harvest sequence: The water pump will
energize and flow water over the evaporators.
The water fill valve and water pump remain on until all
bin switches have been activated, or until the 7-minute
Harvest sequence time limit is reached.
Part Number STH026 6/15