even with fewer than four devices. The LSIU40SE
autotermination scheme is designed to operate properly
when plugging the end connector of the SCSI cables into
the LSIU40SE SCSI connectors.
If you connect the LSIU40SE in the middle of the bus, you
will incur improper termination since the switches are not
assigned on that bus correctly. Refer to
Section 2.2.10.1,
"Channel Switches,"
for more information.
2-8
Installing the LSIU40SE